Specs at a glance
Process temperature: Non-contact installation: any
Within installation:
-40°C…+70°C (-40°F…+158°F)
With high temperature adapter:
up to +450°C (+842°F)
Process pressure / max. overpressure limit: Non-contact installation: any
Within installation:
0.5 bar…6.8 bar (7.2 psi…99 psi) abs.
With high pressure adapter:
up to +21 bar (+305 psi) abs.
Min. density of medium: Solid weight: > 10 g/l
—————————————-
Field of application
Endress Hauser’s
The Soliwave FQR56 microwave barrier uses a contact-free procedure for detection of point levels. It can be installed in containers, conduits, shafts or on free fall shafts. It is possible to take a measurement through non-metallic container materials from the outside. Suitable as point level switch for controlling and counting all types of bulk solids. It interacts with the Soliwave FDR56 receiver.
• Process connections: Threads
• Ambient temperature: -40 to +70°C (-40 to +158°F)
• Measuring range: Max. 100m (328ft)
• International explosion protection certificates