Specs at a glance
Process temperature: -80 °C … +200 °C
(-112 °F … +392 °F)
Process pressure / max. overpressure limit: Vacuum … 100 bar
(Vacuum … 1450 psi)
—————————————-
Field of application
Endress Hauser’s
Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials – this guarantees a high safety standard.
• Process connections: Flanges, threads, special hygienic process connections
• Temperature: -80 to +200°C (-112 to +392°F)
• Pressure: Vacuum to +100bar (vacuum to +1,450psi)
• Sensor length: 12m (39ft)
• International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval
There are no reviews yet.