Specs at a glance
Max. measurement error: Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm3
Measuring range: 0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range: –50 to +200 °C (–58 to +392 °F)
Max. process pressure: PN 40, Class 300, 10K, 400 bar (5800 psi)
Wetted materials: Measuring tube: 1.4539 (904L)
Connection: 1.4539 (904L); 1.4404 (316/316L)
—————————————-
Field of application
Cubemass DCI is the proven sensor for the measurement of smallest flow rates in skids, test rigs and industrial robotics, e.g. in applications like lacquering or surface finishing. Neither high pressure nor alternating flow conditions compromise its accuracy. Equipment manufacturers value Cubemass CDI as compact Coriolis sensor with various communication possibilities.
• Measuring principle operates independently of physical fluid properties such as viscosity or density
• Measuring accurately smallest quantities of liquids and gases
• Nominal diameter: DN 1 to 6 (1/24 to 1/4″)
• Process pressure up to 400 bar (5800 psi)
• Medium temperature up to +200 °C (+392 °F)
• Device as compact or remote version
• Flexible outputs
• Modbus RS485
Device properties