Specs at a glance
Measuring range: 100 µS/cm to 2000 mS/cm
Cell constant k: 6.3 1/cm
Process temperature: -10 °C to 125 °C (14 °F to 257 °F)
Sterilization: 150 °C at 6 bar abs for max. 60 min
(302 °F at 87 psi abs for max. 60 min)
Process pressure: 13 bar abs up to 90 °C (188.5 psi abs up to 194 °F)
9 bar at 125 °C (130.5 psi abs at 257 °F)
—————————————-
Field of application
Endress Hauser’s
The Indumax CLS54D inductive conductivity sensor protects all of your products and processes that must meet the strictest hygienic and sterile demands. Its outstanding performance combined with a unique hygienic design ensures highest safety and quality of your products. Thanks to Memosens digital technology, Indumax CLS54D combines maximum process and data integrity with simple operation. It resists corrosion and moisture, enables lab calibration, and facilitates predictive maintenance.
• Phase separation of product/water and product/product mixtures in pipe systems
• Control of CIP (cleaning in place) processes in the return channel
• Concentration control in remaking of CIP cleaning agents
• Product monitoring in pipe systems, bottling plants, quality assurance
• Leakage monitoring
There are no reviews yet.