Specs at a glance
Accuracy: Standard 0.1%
Optional 0.075%
Process temperature: -10°C…+100°C
(+14°F…+212°F)
Pressure measuring range: 100 mbar…10 bar
(1.5 psi…150 psi)
Process pressure / max. overpressure limit: 40 bar (600 psi)
Main wetted parts: Alloy C
316L
Max. measurement distance: 100 m (328 ft) H2O
Material process membrane: 316L, AlloyC,
Gold-Rhodium
Measuring cell: 100 mbar…10 bar
(1.5 psi…150 psi)
—————————————-
Field of application
The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.
• Process connections: Threads, flanges and hygienic connections
• Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
• Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
• Accuracy: ±0.075%
• International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals