Specs at a glance
Accuracy: class A acc. to IEC 60751
Response time: t50 = 1 s
t90 = 1.5 s
Max. process pressure (static): at 20 °C: 50 bar (725 psi)
Operating temperature range: PT 100:
-50 °C …200 °C
(-58 °F …392 °F)
Max. immersion length on request: up to 600,00 mm (23,62”)
—————————————-
Field of application
Endress Hauser’s
iTHERM CompactLine TM311 sanitary thermometer provides accurate and fast process temperature measurements in hygienic and aseptic applications. Its temperature sensor offers a 4-wire connection or feeds into a smart temperature transmitter with 4 to 20 mA, IO-Link (auto-detect) or switch output. Featuring TipSens technology, the RTD (Pt100; Class A) delivers response times as low as 1.5 s (t90) for optimum process control. This versatile device is a great choice to drive plant standardization.
• Developed for universal use in sterile applications
• High standardization potential for skid builders, machine and plant manufacturers
• Measuring range: -50 to 200 °C (-58 to 392 °F)
• Pressure range: Up to 50 bar (725 psi)
• Protection class: IP69
• Output: Pt100 (4-wire connection); IO-Link, 4 to 20 mA, 1x PNP switch
• International approvals: 3-A, EHEDG, ASME BPE, FDA, EC 1935/2004, EN 2023/2006, TSE/ADI, GB4806-2016, GB9685-2016; Marine approval acc. to DNV GL
There are no reviews yet.