Specs at a glance
Max. measurement error: Volume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
Measuring range: Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
Medium temperature range: 0 to +80 °C (+32 to +176 °F)
Max. process pressure: 11 bar a (159 psi a)
Wetted materials: Sensor: 1.4404/1.4435 (316L)
Transducer: HNBR
Temperature sensor (option): AFM 34
—————————————-
Field of application
Endress Hauser’s
Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of gas flow as well as gas quality. In addition to efficient process control and energy balancing, Heartbeat Technology enables compliance and process safety at all times.
• The measuring principle is unaffected by gas composition
• Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions.
• Multivariable device: flow, temperature and methane
• Medium temperature: 0 to 80 °C (32 to 176 °F)
• Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a)
• Loop-powered technology
• Robust dual-compartment housing
• Plant safety: worldwide approvals
Device properties:
There are no reviews yet.