Specs at a glance
Max. measurement error: Volume flow:
– ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
– ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
Measuring range: 0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
Medium temperature range: 0 to 150° (17.8 to 302 °F)
Max. process pressure: PN 25 / ASME Cl. 150
Wetted materials: Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
----------------------------------------
Field of application
Endress Hauser's
Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
• The measuring principle is independent of pressure, density, temperature and conductivity
• Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines
• Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)
• Process temperatures up to 150 °C (302 °F)
• Entire meter housing made of stainless steel
• 4-20 mA HART, pulse/frequency output
• Local display for reading and monitoring available
• Robust transmitter housing
Device properties:
There are no reviews yet.