Specs at a glance
Max. measurement error: 3 % o.r.
4 % o.r.
5 % o.f.s.
(depending on chosen option of ordering feature “Calibration flow”)
Measuring range: 20 to 720 000 kg/h (45 to 1 587 600 lb/h)
20 to 1 080 000 kg/h (45 to 2 381 400 lb/h)
(for air, depending on chosen option of ordering feature “Calibration flow”)
Medium temperature range: –40 to +100 °C (–40 to +212 °F)
Max. process pressure: 20 bar g (290 psi g)
Wetted materials: Transducer: 1.4404 (316L)
Insertion tube: 1.4404 (316L); 1.4435 (316L)
Connection:
Compression fitting: 1.4404 (316L)
Sealing ring: EPDM; HNBR; 1.4401 (316)
Clamping ring: PEEK 450G
—————————————-
Field of application
Endress Hauser’s
The t-mass B 150 insertion version is suitable for large pipelines or rectangular ventilation ducts. It is designed for the cost-effective measurement of utility gases, in particular compressed air. It is a trending device aimed at sub-metering applications. Its 4-wire technology is contained within a rugged compact aluminum housing. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
• Measuring principle is characterized by a high operable flow range and direct mass flow measurement
• Suitable for air, nitrogen, carbon dioxide and argon in circular piping or rectangular ducts.
• Insertion version for nominal diameter DN 80 to 1500 (3 to 60″)
• Installation and removal of sensor without process interruption
• Easy installation
• Device in compact version with DC 24 V power supply
• 4-20 mA HART, pulse/frequency/switch output
• Compact and robust transmitter
Device properties
There are no reviews yet.