Specs at a glance
Accuracy: +/- 2 mm (0.08 in)
Process temperature: -196…+200 °C
(-321…+392 °F)
Process pressure / max. overpressure limit: Vacuum…25 bar
(Vacuum…363 psi)
Max. measurement distance: Standard: 40 m (131 ft)
With advanced dynamics: 60 m (197 ft)
Main wetted parts: PTFE
—————————————-
Field of application
Endress Hauser’s
For applications in aggressive liquids Micropilot FMR52 offers extraordinary advantages with its completely PTFE-filled and flush-mounted horn antenna. The FMR52 is also the sensor for hygiene-sensitive applications in the food and life sciences industry – ASME BPE, USP Class VI, 3-A and EHEDG approvals. Micropilot is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
• Process connections: Flush-mounted with cladded flange, process connections for hygiene requirements (Tri-Clamp, 11851)
• Temperature: -196 to +200°C (-320,8 to +392°F)
• Pressure: -1 to +25bar (-14.5 to +362psi)
• Maximum measuring range: 40m (131ft), 60m (197ft) for enhanced dynamics
• Accuracy: ±2mm
• K-band: 26GHz
• International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval