Product series
:
Altivar Process ATV900
Device application
:
Industrial Application
Product or component type
:
Variable Speed Driver
Product destination
:
Synchronous motors
Asynchronous motors
Product Special Application
:
Industrial process
Number of Network Phase
:
3 phases
Monophase
Assembly type
:
Wall -mounted
Communication Port Protocol
:
Ethernet IP MODBUS TCP
Modbus
[US] Nominal Nutrition Voltage
:
380 … 480 V – 15 … 10
Motor Power KW
:
Normal condition for 132.0 kW
Heavy condition for 110.0 kW
Motor Power HP
:
Normal requirement for 200.0 hp
Heavy condition for 150.0 HP
Continuous output current
:
Normal requirement for 250 a -de 4 kHz
211 A -DE 4 KHZ for heavy condition
EMC filter
:
Integrated
With EMC Plate Option
IP Protection Class
:
IP21
Protection class
:
Ul type 1
Option module
:
Yuva A: Profibus DP v1 for communication module
Yuva A: Profinet for communication module
Yuva A: Devicenet for communication module
Yuva A: Ethercat for communication module
Yuva A: Canopen Daisy chain for communication module RJ45
Yuva A: Canopen Sub-D 9 for communication module
Yuva A: Canopen screw terminals for communication module
Nest A Yuva B Yuva C: Digital and Analog G çi Expansion Module
Yuva A Yuva B Yuva C: Output Relay Expansion Module
Yuva B: 5 12 V Digital ENCODER INTERVIE MODULE
Yuva B: Analog Encoder Interface Module
Yuva B: Solving Enkoder Interface Module
Asynchronous motor control profile
:
Fixed torque standard
Variable moment standard
Optimum Moment Mode
Maximum output frequency
:
599 Hz
Switching frequency
:
1 … 8 khz adjustable
2.5 … 8 kHz depreciation factor
Nominal switching frequency
:
2.5 khz
Line flow
:
237,0 A -DE 380 V (normal condition)
201.0 A -de 380 V (heavy condition)
213,0 A -DE 480 V (normal condition)
165,0 A -DE 480 V (heavy condition)
Visible power
:
161.4 KVA 380 … 480 V (normal condition)
121.8 kva 380 … 480 V (heavy condition)
Maximum temporary current
:
60 s (normal condition) during 300 A
60 S (heavy condition) during 317 A
Network frequency
:
50 … 60 Hz
Possible line ISC
:
50 KA
Complementary features
Number of digital inputs
:
10
Relay output type
:
Configurable Relay Lojiki R1: Electrical durability of error relay 100000 Cycles
Configurable Relay Lojiki R2: Electrical resistance to Sequence Relay 1000000 Cycles
Configurable Relay Lojiki R3: Electrical resistance to Sequence Relay 1000000 Cycles
Physical interface
:
Ethernet
2 wire RS 485
Connector type
:
2 RJ45
1 RJ45
Access method
:
SLAVE MODBUS TCP
Transmission rate
:
10, 100 Mbits
4.8 KBPS
9600 bit S
19200 bit S
Transmission frame
:
Rtu
Number of Addresses
:
1 247
Data format
:
8 bit, configurable single, double or without parity
Polarization type
:
No impedance
Acceleration and slowing ramps
:
Linear Adjustable Separately from 0.01 … 9999 S
S, U or customized
Motor slip compensation
:
Adjustable
AUTOMATICS ALL KINDING LOAD
Compressible
Continuous magnetic engine law is not available
Braking until it stops
:
With DC Injection
Maximum input current
:
237,0 A
Maximum output voltage
:
480.0 V
Relative symmetrical network frequency tolerance
:
5
Base load current at high load
:
211,0 A
Low -overload base load current
:
250,0 A
Protection type
:
Thermal protection: engine
Secure torque closing: engine
Motor Phase Cutting: Motor
Thermal protection: driver
Secure torque closing: Driver
Overheating: Driver
Over Current Between Output Phase and Earth: Driver
Overload of the output voltage: Driver
Short Circuit Protection: Driver
Motor Phase Cutting: Driver
Excessive voltages in DC data: Driver
Line Feeding Excess Tension: Driver
Low Feeding Low Voltage: Driver
Line Feeding Phase Loss: Driver
Excessive Speed: Driver
Cutting in the control circuit: drive
Quantity per set
:
1
Width
:
320 mm
Height
:
1205 mm
Depth
:
393 mm
Product weight
:
104 kg
Electric connection
:
Line side: screw terminal 2 x 70 … 3 x 120 mm² 2 x awg 2 0 … 2 x 300 kcmil
DC BARA: Screw terminal 0.5 … 1.5 mm² AWG 20 … AWG 16
Control: Screw terminal 0.5 … 1.5 mm² AWG 20 … AWG 16
Transmission rate
:
Ethernet IP MODBUS TCP for 10, 100 Mbit S
4.8, 9.6, 19,2, 38.4 kbit Sn Modbus Series
Data format
:
8 bit, configurable single, double or without parity Modbus series for
Polarization type
:
Modbus series for no impedance
Number of Addresses
:
Modbus series for 1 247
Local signaling
:
Local Diagnostic: 3 LED (single two color)
5 LED (Two Color)
2 LEDs (two color)
1 LED (Red)
Insulation
:
Terminals between power and control
Speed Control Devices
Order by WhatsApp
Schneider ATV930C13N4 132KW speed controller
Variable speed drive, Altivar Process ATV900, ATV930, 132 kW, 380…480 V, with braking unit, IP20 – SCHNEIDER quality product.
×