Specs at a glance
Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230
Response time: depending on configuration
63% rt = 15 s
Max. process pressure (static): at 20°C : 500bar (7.252 psi)
depends on configuration
Operating temperature range: Type T:
-270 °C …400 °C
(-454 °F …752 °F)
Type J:
-210 °C …1200 °C
(-346 °F …2.192 °F)
Type E:
-270 °C …1.000 °C
(-454 °F …1.832 °F)
Type K:
-270 °C …1.372 °C
(-454 °F …2.500 °F)
Type N:
-270 °C …1.300 °C
(-454 °F …2.372 °F)
Max. immersion length on request: up to 22.5″ (571 mm)
others on request
—————————————-
Field of application
Endress Hauser’s
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.
• Chemicals
• Petrochemical
• Refineries
• Offshore Platforms
There are no reviews yet.