Specs at a glance
Accuracy: Standard acc. to ASTM E-230
Special acc. to ASTM E-230
Response time: depending on configuration
63% rt = 15 s
Max. process pressure (static): at 20°C: 100 bar (1.450psi)
depends on configuration
Operating temperature range: Type T:
-270 °C …400 °C
(-454 °F …752 °F)
Type J:
-210 °C … 1.200 °C
(-346 °F …2.192 °F)
Type E:
-270 °C … 1.000 °C
(-454 °F …1.832 °F)
Type K:
-270 °C …1.372 °C
(-454 °F …2.500 °F)
Type N:
-270 °C … 1.300 °C
(-454 °F …2.372 °F)
Max. immersion length on request: up to 24” (609 mm)
others on request
—————————————-
Field of application
Endress Hauser’s
The high modular thermometer is used for several applications with harsh environments, e.g. in power plants, refineries or in the chemical or petrochemical industry. The robust device with barstock thermowell and different head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability. A variety of process connections, dimensions and materials, like SS316, INCONEL600, Hastelloy C276, Titan or Monel, offer flexible application possibilities.
• Chemicals
• Petrochemicals
• Power plants
• Refineries
• Offshore platforms
There are no reviews yet.