Specs at a glance
Process temperature: -50°C … 180°C
(-58°F … 356°F)
Process pressure / max. overpressure limit: Vacuum … 25 bar
(Vacuum … 362 psi)
—————————————-
Field of application
Solicap FTI55 is a fully/partly insulated and robust rod probe for point level detection of fine-grained to coarse-grained bulk solids. It offers maximum reliability due to its active build-up compensation and is suited for a wide range of applications thanks to numerous certificates and approvals. Due to its robust construction, it can also be used to provide accurate measurements in applications with very high lateral loads up to 300Nm.
• Process connections: Flanges and threads
• Measurement range: 200 to 4,000mm (4 to 157″)
• Temperature: -50 to +180°C (-58 to +356°F)
• Pressure: -1 to +25bar (-14.5 to +363psi)
• International explosion protection certificates, SIL
There are no reviews yet.