Specs at a glance
Accuracy: +/- 6 mm (0.24 in)
Process temperature: -40…+150 °C
(-40…+302 °F)
Process pressure / max. overpressure limit: Vacuum…40 bar
(Vacuum…580 psi)
Max. measurement distance: Standard: 20 m (66 ft)
Main wetted parts: PTFE, PVDF
—————————————-
Field of application
Endress Hauser’s
Micropilot FMR53 for simple level measurement applications in liquids. With its slim rod antenna, FMR53 free space radar is particularly suited for small process connections. The PTFE coating of the rod antenna and flange plating guarantee resistance also in aggressive media. The Micropilot FMR53 is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
• Process connections: Thread or flange
• Temperature: -40 to +150°C (–40 to +302°F)
• Pressure range: -1 to +40bar (–14.5 to +580psi)
• Maximum measuring range: 20m (66ft)
• Accuracy: ±6mm
• C-band: 6GHz
• International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol
There are no reviews yet.