Specs at a glance
Number of applications: Support up to 4 gas runs or 2 liquid runs per module (Flow-X/M, Flow-X/C)
Inputs: 6x analog transmitter input, high accuracy
Input types are 4 to 20 mA, 0 to 20 mA, 0 to 5 V, 1 to 5 V
Accuracy mA inputs; 0.002% FS at 21 °C, 0.008% at full ambient range of 0-60 °C, long-term
stability 0.01% per year
Resolution: 24 bits. Analog inputs have the same earthing relative to all other electronic devices.
16x digital status inputs. Resolution 100ns (10MHz)
Outputs: 4x analog output for process outputs and flow / pressure control. Resolution 14 bits, 0.075% FS.
Analog outputs share same ground floating in relation to all other electronics.
16x digital output, open collector. Rating 100mA @24V
—————————————-
Field of application
Endress Hauser’s
The Flow-X flow computer provides gas volume conversion, event logging, parameter logging, and reports using state-of-the-art technology. Identical modules are combined in different housings, offering a multi-stream version Flow-X/P for 1 – 4 measuring distances with a local touch screen, or the version Flow-X/S for smaller installations with one measuring distance. It is the ideal partner for custody transfer gas metering solutions in installations with FLOWSIC600 ultrasonic gas flowmeters.
• Custody gas metering
• Demanding natural gas and process gas applications
• MID approved configuration for gas metering streams with FLOWSIC600
• Powerful modules for demanding applications
• Each module features CPU, memory and equal in/outputs
• Intuitive user interface for graphics display and web browser
• True remote access via Ethernet
• Station computer for multiple streams
Device properties:
There are no reviews yet.