ATV310HU30N4E
Schneider Electric Altivar 310 variable speed drive ATV310, 3 kW, 4 hp, 380...460 V, 3 phase.
إظهار المواصفات
Main Characteristics
| Range of product | Altivar 310 |
|---|---|
| Product or component type | Variable speed drive |
| Product specific application | Simple machine |
| Assembly style | With heat sink |
| Network number of phases | Three phase |
| [Us] rated supply voltage | 380...460 V - 15...10 % |
| Motor power kW | 3 kW for heavy duty; 4 kW for normal duty |
| Motor power hp | 4 hp for heavy duty; 5 hp for normal duty |
| Noise level | 50 dB |
Technical Data
| Quantity per set | Set of 1 |
|---|---|
| EMC filter | Without EMC filter |
| Type of cooling | Integrated fan |
| Communication port protocol | Modbus |
| Connector type | RJ45 (on front face) for Modbus |
| Physical interface | 2-wire RS 485 for Modbus |
| Transmission frame | RTU for Modbus |
| Transmission rate | 4800 bit/s; 9600 bit/s; 19200 bit/s; 38400 bit/s |
| Number of addresses | 1…247 for Modbus |
| Communication service | Read holding registers (03) 29 words; Write single register (06) 29 words; Write multiple registers (16) 27 words; Read/write multiple registers (23) 4/4 words; Read device identification (43) |
| Line current | 11.1 A at 380 V (heavy duty); 14.2 A at 380 V (normal duty); 9.2 A at 460 V (heavy duty); 11.6 A at 460 V (normal duty) |
| Apparent power | 7.3 kVA at 460 V (heavy duty); 9.3 kVA at 460 V (normal duty) |
| Prospective line Isc | 5 kA ( heavy duty ); 5 kA ( normal duty ) |
| Continuous output current | 7.1 A heavy duty; 8.9 A normal duty |
| Maximum transient current | 10.7 A during 60 s (heavy duty); 9.8 A during 60 s (normal duty) |
| Power dissipation in W | 90.8 W, at In (heavy duty); 120.4 W, at In (normal duty) |
| Speed drive output frequency | 0.5…400 Hz |
| Nominal switching frequency | 4 kHz |
| Switching frequency | 2...12 kHz adjustable |
| Speed range | 1…20 for asynchronous motor |
| Transient overtorque | 170…200 % of nominal motor torque depending on drive rating and type of motor |
| Braking torque | Up to 150 % of nominal motor torque with braking resistor; Up to 70 % of nominal motor torque without braking resistor |
| Asynchronous motor control profile | Voltage/frequency ratio (V/f); Voltage/frequency ratio - Energy Saving, quadratic U/f; Sensorless vector control (SVC) |
| Motor slip compensation | Adjustable |
| Output voltage | 380...460 V three phase |
| Electrical connection | Terminal, clamping capacity: 1.5...4 mm², 16 AWG...12 AWG (L1, L2, L3, PA/+, PB, U, V, W) |
| Tightening torque | 1.2…1.4 N.m |
| Insulation | Electrical between power and control |
| Supply | Internal supply for reference potentiometer: 5 V (4.75…5.25 V)DC, <10 mA with overload and short-circuit protection; Internal supply for logic inputs: 24 V (20.4…28.8 V)DC, <100 mA with overload and short-circuit protection |
| Analogue input number | 1 |
| Analogue input type | Configurable current AI1 0...20 mA 250 Ohm; Configurable voltage AI1 0...10 V 30 kOhm; Configurable voltage AI1 0...5 V 30 kOhm |
| Discrete input number | 4 |
| Discrete input type | Programmable LI1...LI4 24 V 18...30 V |
| Discrete input logic | Negative logic (sink), > 16 V (state 0), 11 V (state 1) |
| Sampling duration | 10 ms for analogue input; 20 ms, tolerance +/- 1 ms for logic input |
| Linearity error | +/- 0.3 % of maximum value for analogue input |
| Analogue output number | 1 |
| Analogue output type | AO1 software-configurable voltage: 0...10 V AC 0...10 V 0…0.02 A, impedance: 470 Ohm, resolution 8 bits; AO1 software-configurable current: 0...20 mA, impedance: 800 Ohm, resolution 8 bits |
| Discrete output number | 2 |
| Discrete output type | Logic output LO+, LO-; Protected relay output R1A, R1B, R1C 1 C/O |
| Minimum switching current | 5 mA at 24 V DC for logic relay |
| Maximum switching current | 2 A at 250 V AC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay; 2 A at 30 V DC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay; 3 A at 250 V AC on resistive load cos phi = 1 L/R = 0 ms for logic relay; 4 A at 30 V DC on resistive load cos phi = 1 L/R = 0 ms for logic relay |
| Acceleration and deceleration ramps | Linear from 0...999.9 s; S; U |
| Braking to standstill | By DC injection, <30 s |
| Protection type | Line supply overvoltage; Line supply undervoltage; Overcurrent between output phases and earth; Overheating protection; Short-circuit between motor phases; Against input phase loss in three-phase; Thermal motor protection via the drive by continuous calculation of I²t |
| Frequency resolution | Analog input: converter A/D, 10 bits; Display unit: 0.1 Hz |
| Time constant | 20 ms +/- 1 ms for reference change |
| Operating position | Vertical +/- 10 degree |
| Height | 184 mm |
| Width | 140 mm |
| Depth | 151 mm |
| Net weight | 1.8 kg |
| Supply frequency | 50/60 Hz +/- 5 % |
| Product destination | Asynchronous motors |
Environment & Certifications
| Electromagnetic compatibility | Electrical fast transient/burst immunity test - test level: level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test - test level: level 3 conforming to IEC 61000-4-2; Immunity to conducted disturbances - test level: level 3 conforming to IEC 61000-4-6; Radiated radio-frequency electromagnetic field immunity test - test level: level 3 conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Surge immunity test - test level: level 3 conforming to IEC 61000-4-5 |
|---|---|
| Standards | IEC 61800-3 |
| Product certifications | CE; EAC; KC |
| IP degree of protection | IP20 without blanking plate on upper part; IP4X top |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Environmental characteristic | Dust pollution resistance class 3S2 conforming to IEC 60721-3-3; Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 |
| Shock resistance | 15 gn conforming to IEC 60068-2-27 for 11 ms |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for storage | -25…70 °C |
| Ambient air temperature for operation | -10…55 °C without derating; 55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C |
| Operating altitude | <= 1000 m without derating |
Packaging & Logistics
| Number of Units in Package 1 | 1 |
|---|---|
| Package 1 Height | 19.000 cm |
| Package 1 Width | 18.500 cm |
| Package 1 Length | 23.000 cm |
| Package 1 Weight | 2.116 kg |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

ATV310HU30N4E
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.