ATV340D11N4
Schneider Electric variable speed drive, Altivar Machine ATV340, 11kW, heavy duty, 400V, 3 phases.
إظهار المواصفات
Main Characteristics
| Range of Product | Altivar Machine ATV340 |
|---|---|
| Product or Component Type | Variable speed drive |
| Product Specific Application | Machine |
| Mounting Mode | Cabinet mount |
| Variant | Standard version |
| Communication Port Protocol | Modbus serial |
| Option card | communication module, Profibus DP V1; communication module, PROFINET; communication module, DeviceNet; communication module, CANopen; communication module, EtherCAT |
| Phase | 3 phase |
| Supply frequency | 50...60 Hz +/- 5 % |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| Nominal output current | 24.0 A |
| Motor power kW | 15 kW normal duty; 11 kW heavy duty |
| Maximum Horse Power Rating | 20 hp normal duty; 15 hp heavy duty |
| EMC filter | Class C3 EMC filter integrated |
| IP degree of protection | IP20 |
Technical Data
| Discrete input number | 5 |
|---|---|
| Discrete input type | PTI programmable as pulse input 0…30 kHz, 24 V DC 30 V); DI1...DI5 programmable, 24 V DC 30 V)3.5 kOhm |
| Number of preset speeds | 16 preset speeds |
| Discrete output number | 2.0 |
| Discrete output type | Programmable output DQ1, DQ2 30 V DC 100 mA |
| Analogue input number | 2 |
| Analogue input type | AI1 software-configurable current 0...20 mA 250 Ohm 12 bits; AI1 software-configurable temperature probe or water level sensor; AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits; AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits |
| Analogue output number | 1 |
| Analogue output type | Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits; Software-configurable current AQ1 0...20 mA 500 Ohm 10 bits |
| Relay output number | 2 |
| Output voltage | <= power supply voltage |
| Relay output type | Relay outputs R1A; Relay outputs R1C 100000 cycles; Relay outputs R2A; Relay outputs R2C 100000 cycles |
| Maximum switching current | Relay output R1C resistive, cos phi = 1 3 A 250 V AC; Relay output R1C resistive, cos phi = 1 3 A 30 V DC; Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC; Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC; Relay output R2C resistive, cos phi = 1 5 A 250 V AC; Relay output R2C resistive, cos phi = 1 5 A 30 V DC; Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC; Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
| Minimum switching current | Relay output R1B 5 mA 24 V DC; Relay output R2C 5 mA 24 V DC |
| Physical interface | 2-wire RS 485 |
| Connector Type | 1 RJ45 |
| Method of access | Slave Modbus RTU |
| Transmission Rate | 4.8 kbit/s; 9.6 kbit/s; 19.2 kbit/s; 38.4 kbit/s |
| Transmission frame | RTU |
| Number of addresses | 1…247 |
| Data format | 8 bits, configurable odd, even or no parity |
| Type of polarization | No impedance |
| 4 quadrant operation possible | True |
| Asynchronous motor control profile | Optimized torque mode; Variable torque standard; Constant torque standard |
| Synchronous motor control profile | Permanent magnet motor; Reluctance motor |
| Pollution degree | 2 IEC 61800-5-1 |
| Maximum output frequency | 0.599 kHz |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01...9999 s; S, U or customized |
| Motor slip compensation | Not available in permanent magnet motor law; Adjustable; Can be suppressed; Automatic whatever the load |
| Switching frequency | 2...16 kHz adjustable; 4...16 kHz with derating factor |
| Nominal switching frequency | 4 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | True |
| Line current | 34.7 A 380 V without line choke heavy duty); 27.7 A 480 V without line choke heavy duty); 33.9 A 380 V with external line choke normal duty); 27.2 A 480 V with external line choke normal duty); 35.1 A 380 V with external line choke heavy duty); 27.8 A 480 V with external line choke heavy duty) |
| Maximum Input Current per Phase | 34.7 A |
| Maximum output voltage | 480 V |
| Apparent power | 22.7 kVA 480 V normal duty); 23 kVA 480 V heavy duty) |
| Maximum transient current | 35.2 A 60 s normal duty); 36 A 60 s heavy duty); 43.2 A 2 s normal duty); 43 A 2 s heavy duty) |
| Electrical connection | Control screw terminal 0.2...2.5 mm² 24 AWG...12 AWG; Line side screw terminal 4...25 mm² 10 AWG...3 AWG; DC bus screw terminal 4...25 mm² 10 AWG...3 AWG; Motor screw terminal 2.5...25 mm² 12 AWG...3 AWG |
| Prospective line Isc | 22 kA |
| Base load current at high overload | 24.0 A |
| Base load current at low overload | 32.0 A |
| Power dissipation in W | Natural convection 13 W 380 V 4 kHz heavy duty); Forced convection 241 W 380 V 4 kHz heavy duty); Natural convection 16 W 380 V 4 kHz normal duty); Forced convection 311 W 380 V 4 kHz normal duty) |
| With safety function Safely Limited Speed (SLS) | True |
| With safety function Safe brake management (SBC/SBT) | True |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | True |
| With sft fct Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | True |
| With safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Protection type | Thermal protection motor; Safe torque off motor; Motor phase loss motor; Thermal protection drive; Safe torque off drive; Overheating drive; Overcurrent drive; Output overcurrent between motor phase and earth drive; Output overcurrent between motor phases drive; Short-circuit between motor phase and earth drive; Short-circuit between motor phases drive; Motor phase loss drive; DC Bus overvoltage drive; Line supply overvoltage drive; Line supply undervoltage drive; Input supply loss drive; Exceeding limit speed drive; Break on the control circuit drive |
| Width | 7.09 in (180.0 mm) |
| Height | 15.2 in (385.0 mm) |
| Depth | 9.8 in (249.0 mm) |
| Net Weight | 20.9 lb(US) (9.5 kg) |
| Continuous output current | 32 A 4 kHz normal duty; 24 A 4 kHz heavy duty |
Environment & Certifications
| Operating altitude | <= 9842.52 ft (3000 m) with current derating above 1000m |
|---|---|
| Operating position | Vertical +/- 10 degree |
| Product Certifications | UL; CSA; TÜV; EAC; CTick |
| Marking | CE |
| Standards | IEC 61800-3; IEC 61800-5-1; IEC 60721-3; IEC 61508; IEC 13849-1; UL 618000-5-1; UL 508C |
| Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 70 m/s² at 22 ms |
| Maximum acceleration under vibrational stress (during operation) | 5 m/s² at 9...200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...9 Hz |
| Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Volume of cooling air | 33814.6 Gal/hr(US) (128.0 m3/h) |
| Type of cooling | Forced convection |
| Overvoltage category | Class III |
| Regulation loop | Adjustable PID regulator |
| Noise level | 55.6 dB |
| Pollution degree | 2 |
| Ambient air transport temperature | -40…158 °F (-40…70 °C) |
| Ambient air temperature for operation | 5…122 °F (-15…50 °C) without derating vertical position); 122…140 °F (50…60 °C) with derating factor vertical position) |
| Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
| Isolation | Between power and control terminals |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 13.386 in (34.000 cm) |
| Package 1 Width | 12.008 in (30.500 cm) |
| Package 1 Length | 22.244 in (56.500 cm) |
| Package weight(Lbs) | 24.705 lb(US) (11.206 kg) |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 29.528 in (75.000 cm) |
| Package 2 Width | 23.622 in (60.000 cm) |
| Package 2 Length | 31.496 in (80.000 cm) |
| Package 2 Weight | 78.070 lb(US) (35.412 kg) |
| GTIN | 3606480966941 |
| Country of origin | ID |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

ATV340D11N4
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.