Schneider Electric Altivar 61 variable speed drive ATV61, 30kW 40HP, 380...480V, EMC filter, IP54.
إظهار المواصفات
Main Characteristics
| Lifecycle status | Discontinued by the manufacturer |
|---|---|
| Range of product | Altivar 61 |
| Product or component type | Variable speed drive |
| Product specific application | Pumping and ventilation machine |
| Component name | ATV61 |
| Motor power kW | 30 kW |
| Motor power hp | 40 hp |
| Power supply voltage | 380...480 V - 15...10 % |
| Supply number of phases | 3 phases |
| Line current | 46.2 A at 480 V; 56.7 A at 380 V |
| EMC filter | Class C2 EMC filter integrated |
| Assembly style | Enclosed with Vario switch disconnector |
| Apparent power | 37.3 kVA at 380 V |
| Maximum prospective line Isc | 22 kA |
| Maximum transient current | 64.3 A for 60 s |
| Nominal switching frequency | 4 kHz |
| Switching frequency | 2...16 kHz adjustable; 8...16 kHz with derating factor |
| Asynchronous motor control | Flux vector control without sensor, standard; Voltage/frequency ratio, 2 points; Voltage/frequency ratio - Energy Saving, quadratic U/f; Voltage/frequency ratio, 5 points |
| Synchronous motor control profile | Vector control without sensor, standard |
| Communication port protocol | CANopen; Modbus |
| Type of polarization | No impedance for Modbus |
| Option card | Communication card for APOGEE FLN; Communication card for BACnet; Communication card for CC-Link; Controller inside programmable card; Communication card for DeviceNet; Communication card for EtherNet/IP; Communication card for Fipio; I/O extension card; Communication card for Interbus-S; Communication card for LonWorks; Communication card for METASYS N2; Communication card for Modbus Plus; Communication card for Modbus TCP; Communication card for Modbus/Uni-Telway; Multi-pump card; Communication card for Profibus DP; Communication card for Profibus DP V1 |
Technical Data
| Product destination | Asynchronous motors; Synchronous motors |
|---|---|
| Power supply voltage limits | 323…528 V |
| Power supply frequency | 50...60 Hz - 5...5 % |
| Power supply frequency limits | 47.5…63 Hz |
| Continuous output current | 52 A at 4 kHz, 460 V; 58.5 A at 4 kHz, 380 V |
| Speed drive output frequency | 0.5…500 Hz |
| Speed range | 1…100 in open-loop mode, without speed feedback |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback |
| Torque accuracy | +/- 15 % in open-loop mode, without speed feedback |
| Transient overtorque | 130 % of nominal motor torque +/- 10 % for 60 s |
| Braking torque | <= 125 % with braking resistor; 30 % without braking resistor |
| Regulation loop | Frequency PI regulator |
| Motor slip compensation | Not available in voltage/frequency ratio (2 or 5 points); Can be suppressed; Adjustable; Automatic whatever the load |
| Diagnostic | 1 LED (red) for drive voltage |
| Output voltage | <= power supply voltage |
| Electrical isolation | Between power and control terminals |
| Type of cable for mounting in an enclosure | With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC; With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR |
| Electrical connection | Terminal 2.5 mm² / 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); Terminal 25 mm² / 3 AWG (L1/R, L2/S, L3/T); Terminal 50 mm² / 1/0 AWG (U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Tightening torque | 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); 5.4 N.m, 47.7 lb.in (L1/R, L2/S, L3/T); 12 N.m, 106.2 lb.in (U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Supply | Internal supply: 24 V DC (21…27 V), <200 mA with overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 %, <10 mA with overload and short-circuit protection; External supply: 24 V DC (19…30 V) |
| Analogue input number | 2 |
| Analogue input type | AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign; AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits; AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits |
| Sampling time | 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input; 2 ms +/- 0.5 ms (Al2) - analog input; 2 ms +/- 0.5 ms (AO1) - analog output; 2 ms +/- 0.5 ms (LI1...LI5) - discrete input; 2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input |
| Absolute accuracy precision | +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C; +/- 0.6 % (AI2) for a temperature variation 60 °C; +/- 0.6 % (AO1) for a temperature variation 60 °C |
| Linearity error | +/- 0.15 % of maximum value (AI1-/Al1+); +/- 0.15 % of maximum value (AI2); +/- 0.2 % (AO1) |
| Analogue output number | 1 |
| Analogue output type | AO1 software-configurable logic output 10 V, 20 mA; AO1 software-configurable current, analogue output range 0...20 mA, impedance: 500 Ohm, resolution 10 bits; AO1 software-configurable voltage, analogue output range 0...10 V DC, impedance: 470 Ohm, resolution 10 bits |
| Discrete output number | 2 |
| Discrete output type | Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic: (R2A, R2B) NO - 100000 cycles |
| Maximum response time | <= 100 ms in STO (Safe Torque Off); R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms; R2A, R2B <= 7 ms, tolerance +/- 0.5 ms |
| Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| Maximum switching current | 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2); 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2); 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2) |
| Discrete input number | 7 |
| Discrete input type | Programmable (LI1...LI5)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm; Switch-configurable (LI6)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm; Switch-configurable PTC probe (LI6)0…6 probes - 1500 Ohm; Safety input (PWR)24 V DC (<= 30 V) - 1500 Ohm |
| Discrete input logic | Negative logic (sink) (LI1...LI5), > 16 V (state 0), 11 V (state 1); Negative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), 11 V (state 1) |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 s; Automatic adaptation of ramp if braking capacity exceeded, by using resistor; S, U or customized |
| Braking to standstill | By DC injection |
| Protection type | Against exceeding limit speed: drive; Against input phase loss: drive; Break on the control circuit: drive; Input phase breaks: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Overcurrent between output phases and earth: drive; Overheating protection: drive; Overvoltages on the DC bus: drive; Power removal: drive; Short-circuit between motor phases: drive; Thermal protection: drive; Motor phase break: motor; Power removal: motor; Thermal protection: motor |
| Insulation resistance | > 1 mOhm 500 V DC for 1 minute to earth |
| Frequency resolution | Analog input: 0.024/50 Hz; Display unit: 0.1 Hz |
| Connector type | 1 RJ45 (on front face) for Modbus; Male SUB-D 9 on RJ45 (on terminal) for CANopen |
| Physical interface | 2-wire RS 485 for Modbus |
| Transmission frame | RTU for Modbus |
| Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 9600 bps, 19200 bps for Modbus on front face; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen |
| Data format | 8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal |
| Number of addresses | 1…127 for CANopen; 1…247 for Modbus |
| Method of access | Slave CANopen |
| Marking | CE |
| Operating position | Vertical +/- 10 degree |
| Width | 285 mm |
| Height | 720 mm |
| Depth | 335 mm |
| Net weight | 52.8 kg |
Environment & Certifications
| Noise level | 59.9 dB conforming to 86/188/EEC |
|---|---|
| Dielectric strength | 3535 V DC between earth and power terminals; 5092 V DC between control and power terminals |
| Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Standards | IEC 60721-3-3 class 3S2; UL Type 12; EN 55011 class A group 1; EN 61800-3 environments 1 category C2; EN 61800-3 environments 2 category C2; IEC 60721-3-3 class 3C1; EN/IEC 61800-3; EN/IEC 61800-5-1 |
| Product certifications | UL; NOM 117; C-Tick; GOST; CSA; DNV |
| Pollution degree | 3 conforming to EN/IEC 61800-5-1; 3 conforming to UL 840 |
| Degree of proctection | IP54 conforming to EN/IEC 60529; IP54 conforming to EN/IEC 61800-5-1; IP54 conforming to UL Type 12 |
| Vibration resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6; 1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…40 °C (without derating); -10…50 °C (with derating factor) |
| Ambient air temperature for storage | -25…70 °C |
| Operating altitude | <= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m |
Packaging & Logistics
| Number of Units in Package 1 | 1 |
|---|---|
| Package 1 Height | 43.0 cm |
| Package 1 Width | 60.0 cm |
| Package 1 Length | 80.0 cm |
| Package 1 Weight | 47.0 kg |
| Number of Units in Package 2 | 1 |
| Package 2 Height | 43.0 cm |
| Package 2 Width | 42.0 cm |
| Package 2 Length | 80.0 cm |
| Package 2 Weight | 47.0 kg |
| Number of Units in Package 3 | 1 |
| Package 3 Height | 45.0 cm |
| Package 3 Width | 45.0 cm |
| Package 3 Length | 120.0 cm |
| Package 3 Weight | 47.0 kg |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

ATV61E5D30N4
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.