
LC1D129SD
Schneider Electric TeSys Deca Advanced IEC contactor, TeSys D, nonreversing, 12A, 7.5HP at 480VAC, 3 phase, 3 pole, 3 NO, 72VDC coil, open style.
إظهار المواصفات
Main Characteristics
| Range of Product | TeSys Deca Advanced |
|---|---|
| Product or Component Type | Contactor |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz; Power circuit <= 300 V DC |
| [Ie] rated operational current | 25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit; 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit; 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit |
| [Uc] control circuit voltage | 72 V DC |
Technical Data
| Motor power kW | 3 kW at 220/230 V AC 50/60 Hz (AC-3); 5.5 kW at 380/400 V AC 50/60 Hz (AC-3); 5.5 kW at 415/440 V AC 50/60 Hz (AC-3); 7.5 kW at 500 V AC 50/60 Hz (AC-3); 7.5 kW at 660/690 V AC 50/60 Hz (AC-3); 3 kW at 220/230 V AC 50/60 Hz (AC-3e); 5.5 kW at 380/400 V AC 50/60 Hz (AC-3e); 5.5 kW at 415/440 V AC 50/60 Hz (AC-3e); 7.5 kW at 500 V AC 50/60 Hz (AC-3e); 7.5 kW at 660/690 V AC 50/60 Hz (AC-3e); 3.7 kW at 400 V AC 50/60 Hz (AC-4) |
|---|---|
| Maximum Horse Power Rating | 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors; 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors; 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 10 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 25 A (at 140 °F (60 °C)) for power circuit; 10 A (at 140 °F (60 °C)) for signalling circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 104 °F (40 °C) - 10 s for power circuit; 210 A 104 °F (40 °C) - 1 s for power circuit; 30 A 104 °F (40 °C) - 10 min for power circuit; 61 A 104 °F (40 °C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1; 40 A gG at <= 690 V coordination type 1 for power circuit; 25 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 0.36 W AC-3; 1.56 W AC-1; 0.36 W AC-3e |
| [Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 2 Mcycles 12 A AC-3 <= 440 V; 0.8 Mcycles 25 A AC-1 <= 440 V; 2 Mcycles 12 A AC-3e <= 440 V |
| Control circuit type | DC standard |
| Coil technology | With integral suppression device |
| Control circuit voltage limits | 0.1...0.25 Uc (-40…158 °F (-40…70 °C)):drop-out DC; 0.7...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC; 1...1.25 Uc (140…158 °F (60…70 °C)):operational DC |
| Inrush power in W | 5.4 W 68 °F (20 °C)) |
| Hold-in power consumption in W | 5.4 W 68 °F (20 °C) |
| Operating time | 63 ±15 % ms closing; 20 ±20 % ms opening |
| Time constant | 28 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: Faston terminals 1; Power circuit: plug-in connector |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting Support | Plate; Rail |
Environment & Certifications
| Standards | CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 60947-4-1 |
|---|---|
| Product Certifications | UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme |
| IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | THIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C); 140…158 °F (60…70 °C) with derating |
| Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) ; Vibrations contactor closed 4 Gn, 5...300 Hz) ; Shocks contactor open 10 Gn for 11 ms) ; Shocks contactor closed 15 Gn for 11 ms) |
| Height | 3.1 in (80 mm) |
| Width | 1.8 in (45 mm) |
| Depth | 3.7 in (95 mm) |
| Net Weight | 1.069 lb(US) (0.485 kg) |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 4.291 in (10.900 cm) |
| Package 1 Width | 3.543 in (9.000 cm) |
| Package 1 Length | 2.126 in (5.400 cm) |
| Package weight(Lbs) | 17.707 oz (502.000 g) |
| Number of Units in Package 2 | 20 |
| Package 2 Height | 5.9 in (15 cm) |
| Package 2 Width | 11.8 in (30 cm) |
| Package 2 Length | 15.7 in (40 cm) |
| Package 2 Weight | 22.708 lb(US) (10.300 kg) |
| Number of Units in Package 3 | 320 |
| Package 3 Height | 29.528 in (75.000 cm) |
| Package 3 Width | 31.496 in (80.000 cm) |
| Package 3 Length | 23.622 in (60.000 cm) |
| Package 3 Weight | 380.959 lb(US) (172.800 kg) |
| GTIN | 3389110806922 |
| Country of origin | FR |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

LC1D129SD
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.