LC1D150ALSE
Schneider Electric contactor, Tesys Deca Advanced, 3P(3NO), 100hp at 480V, 150A, 200-500V AC/DC coil, Everlink.
إظهار المواصفات
Main Characteristics
| Range | TeSys Deca |
|---|---|
| Range of Product | TeSys Deca Advanced |
| Product or Component Type | Contactor |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4; DC-1; DC-3; DC-5 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit <= 1000 V AC 16.67...400 Hz; Power circuit <= 300 V DC |
| [Ie] rated operational current | 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit; 150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit; 200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 200...500 V AC 50/60 Hz; 200...500 V DC |
Technical Data
| Motor power kW | 40 kW at 230 V AC 50/60 Hz (AC-3); 75 kW at 400 V AC 50/60 Hz (AC-3); 80 kW at 415 V AC 50/60 Hz (AC-3); 90 kW at 440 V AC 50/60 Hz (AC-3); 90 kW at 500 V AC 50/60 Hz (AC-3); 100 kW at 690 V AC 50/60 Hz (AC-3); 75 kW at 1000 V AC 50/60 Hz (AC-3); 40 kW at 230 V AC 50/60 Hz (AC-3e); 75 kW at 400 V AC 50/60 Hz (AC-3e); 80 kW at 415 V AC 50/60 Hz (AC-3e); 90 kW at 440 V AC 50/60 Hz (AC-3e); 90 kW at 500 V AC 50/60 Hz (AC-3e); 100 kW at 690 V AC 50/60 Hz (AC-3e); 75 kW at 1000 V AC 50/60 Hz (AC-3e); 37 kW at 230 V AC 50/60 Hz (AC-4); 75 kW at 400 V AC 50/60 Hz (AC-4); 75 kW at 440 V AC 50/60 Hz (AC-4); 75 kW at 500 V AC 50/60 Hz (AC-4); 80 kW at 690 V AC 50/60 Hz (AC-4); 65 kW at 1000 V AC 50/60 Hz (AC-4) |
|---|---|
| Maximum Horse Power Rating | 40 hp at 200/208 V 60 Hz; 50 hp at 230/240 V 60 Hz; 100 hp at 460/480 V 60 Hz; 125 hp at 575/600 V 60 Hz |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 200 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 1885 A at 440 V for power circuit conforming to IEC 60947; 140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 1440 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 350 A 104 °F (40 °C) - 10 min for power circuit; 600 A 104 °F (40 °C) - 1 min for power circuit; 1280 A 104 °F (40 °C) - 10 s for power circuit; 1800 A 104 °F (40 °C) - 1 s for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 160 A aM at <= 440 V for power circuit; 125 A aM at <= 690 V for power circuit; 250 A gG at <= 690 V for power circuit; 10 A gG for signalling circuit; 0.5 A gG for control circuit |
| Average impedance | 0.45 mOhm - Ith 200 A 50 Hz for power circuit |
| Power dissipation per pole | 8 W AC-3; 8 W AC-3e; 22 W AC-1 |
| [Ui] rated insulation voltage | Power circuit 600 V CSA; Power circuit 600 V UL; Power circuit 1000 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1; B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 0.85 Mcycles 150 A AC-3 <= 440 V; 0.85 Mcycles 150 A AC-3e <= 440 V; 0.5 Mcycles 200 A AC-1 <= 440 V |
| Control circuit type | AC 50/60 Hz; DC |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.8 Uc Min...1.1 Uc Max (-40…140 °F (-40…60 °C)):operational AC/DC; 0.1 Uc Max (-40…140 °F (-40…60 °C)):drop-out AC/DC |
| Inrush power in VA | 170 VA (at 68 °F (20 °C)) |
| Inrush power in W | 120 W 68 °F (20 °C)) |
| Hold-in power consumption in VA | 15.5 VA (at 68 °F (20 °C)) |
| Hold-in power consumption in W | 5.1 W 68 °F (20 °C) |
| Heat dissipation | 3 W at 20 °C |
| Operating time | 10...80 ms opening; 20...90 ms closing |
| Maximum operating rate | 2400 cyc/h at 60 °C; 3600 cyc/h at Uc at 20 ºC |
| Connections - terminals | Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible without cable end; Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible with cable end; Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: solid without cable end; Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end |
| Tightening torque | Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm); Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency | 16.67...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact |
| Mounting Support | Plate |
Environment & Certifications
| Standards | EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; JIS C8201-4-1; JIS C8201-5-1; GB/T 14048.4; GB/T 14048.5 |
|---|---|
| Product Certifications | CB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV-GL |
| IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | NoneIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C) operation; 140…158 °F (60…70 °C) with derating; -76…176 °F (-60…80 °C) storage |
| Operating altitude | 0...9842.52 ft (0...3000 m) without derating |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-11 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) IEC 60068-2-6; Vibrations contactor closed 4 Gn, 5...300 Hz) IEC 60068-2-6; Shocks contactor open 10 Gn for 11 ms) IEC 60068-2-27; Shocks contactor closed 15 Gn for 11 ms) IEC 60068-2-27 |
| Height | 6.0 in (152 mm) |
| Width | 3.8 in (97 mm) |
| Depth | 6.1 in (155 mm) |
| Net Weight | 5.3 lb(US) (2.4 kg) |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 7.4 in (18.9 cm) |
| Package 1 Width | 5.2 in (13.2 cm) |
| Package 1 Length | 7.2 in (18.2 cm) |
| Package weight(Lbs) | 5.82 lb(US) (2.64 kg) |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 11.8 in (30 cm) |
| Package 2 Width | 11.8 in (30 cm) |
| Package 2 Length | 15.7 in (40 cm) |
| Package 2 Weight | 24.4596 lb(US) (11.0947 kg) |
| Number of Units in Package 3 | 24 |
| Package 3 Height | 28.9 in (73.5 cm) |
| Package 3 Width | 23.6 in (60 cm) |
| Package 3 Length | 31.5 in (80 cm) |
| Package 3 Weight | 169.6007 lb(US) (76.9295 kg) |
| GTIN | 3606486977064 |
| Country of origin | CN |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

LC1D150ALSE
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.