LC1D506BD
Schneider Electric TeSys Deca Advanced IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style.
إظهار المواصفات
Main Characteristics
| Range | TeSys |
|---|---|
| Range of Product | TeSys Deca Advanced |
| Product or Component Type | Contactor |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4; AC-2 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz |
| [Ie] rated operational current | 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit; 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit; 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit |
| [Uc] control circuit voltage | 24 V DC |
Technical Data
| Motor power kW | 15 kW at 220/230 V AC 50/60 Hz (AC-3); 22 kW at 380/400 V AC 50/60 Hz (AC-3); 25 kW at 415 V AC 50/60 Hz (AC-3); 30 kW at 440 V AC 50/60 Hz (AC-3); 30 kW at 500 V AC 50/60 Hz (AC-3); 33 kW at 660/690 V AC 50/60 Hz (AC-3); 30 kW at 1000 V AC 50/60 Hz (AC-3) |
|---|---|
| Maximum Horse Power Rating | 3 hp at 115 V AC 60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors; 15 hp at 200/208 V AC 60 Hz for 3 phase motors; 15 hp at 230/240 V AC 60 Hz for 3 phase motors; 40 hp at 460/480 V AC 60 Hz for 3 phase motors; 40 hp at 575/600 V AC 60 Hz for 3 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for control circuit; 80 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 250 A DC for control circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity | 900 A at 440 V for power circuit conforming to IEC 60947 |
| Associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1; 100 A gG at <= 690 V coordination type 1 for power circuit; 100 A gG at <= 690 V coordination type 2 for power circuit |
| Power dissipation per pole | 3.7 W AC-3; 9.6 W AC-1; 3.7 W AC-3e |
| [Ui] rated insulation voltage | Control circuit 600 V CSA; Control circuit 600 V UL; Power circuit 600 V CSA; Power circuit 600 V UL; Control circuit 690 V IEC 60947-1; Power circuit 690 V IEC 60947-1 |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Control circuit type | DC standard |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC; 0.75...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC; 1...1.25 Uc (140…158 °F (60…70 °C)):operational DC |
| Inrush power in W | 19 W 68 °F (20 °C)) |
| Hold-in power consumption in W | 7.4 W 68 °F (20 °C) |
| Rated operational power in W | 14 W 24 V DC-13 10000000 cycles - control circuit; 48 W 24 V DC-13 3000000 cycles - control circuit; 96 W 24 V DC-13 1000000 cycles - control circuit |
| Operating time | 20 ±20 % ms opening; 50 ±15 % ms closing |
| Time constant | 34 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm); Power circuit: lugs-ring terminals - external diameter: 0.6 in (16 mm) |
| Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) lugs Philips No 2; Control circuit 15.05 lbf.in (1.7 N.m) lugs flat Ø 6 mm; Power circuit 22.1 lbf.in (2.5 N.m) lugs flat Ø 8 mm; Control circuit 15.05 lbf.in (1.7 N.m) lugs pozidriv No 2 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1 |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contacts; 1.5 ms on energisation between NC and NO contacts |
| Mounting Support | Rail; Plate |
Environment & Certifications
| Standards | EN 60947-5-1; UL 60947-4-1; IEC 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; EN 60947-4-1 |
|---|---|
| Product Certifications | LROS (Lloyds register of shipping); GOST; CCC; RINA; GL; UL; DNV; CSA; BV |
| IP degree of protection | IP2X IEC 60529; IP2X VDE 0106 |
| Climatic withstand | IACS E10 exposure to damp heat |
| Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Shocks contactor opened 10 Gn for 11 ms) ; Shocks contactor closed 15 Gn for 11 ms) ; Vibrations contactor opened 2 Gn, 5...300 Hz) ; Vibrations contactor closed 4 Gn, 5...300 Hz) |
| Height | 5 in (127 mm) |
| Width | 3.3 in (85 mm) |
| Depth | 6.9 in (176 mm) |
| Net Weight | 4.817 lb(US) (2.185 kg) |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 7.283 in (18.500 cm) |
| Package 1 Width | 5.512 in (14.000 cm) |
| Package 1 Length | 3.543 in (9.000 cm) |
| Package weight(Lbs) | 4.828 lb(US) (2.190 kg) |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 5.9 in (15 cm) |
| Package 2 Width | 11.8 in (30 cm) |
| Package 2 Length | 15.7 in (40 cm) |
| Package 2 Weight | 10.229 lb(US) (4.640 kg) |
| Number of Units in Package 3 | 32 |
| Package 3 Height | 29.528 in (75.000 cm) |
| Package 3 Width | 31.496 in (80.000 cm) |
| Package 3 Length | 23.622 in (60.000 cm) |
| Package 3 Weight | 181.308 lb(US) (82.240 kg) |
| GTIN | 3389110957914 |
| Country of origin | CZ |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

LC1D506BD
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.