LTMR27CBD
Schneider Electric motor controller, TeSys T, Motor Management, CANopen, 6 logic inputs, 3 relay logic outputs, 1.35 to 27A, 24VDC.
إظهار المواصفات
Main Characteristics
| Lifecycle status | Discontinued by the manufacturer |
|---|---|
| Range | TeSys |
| Product name | TeSys T |
| Product or Component Type | Motor controller |
| Device Application | Equipment monitoring and control |
| Measurement current | 1.35…27 A |
| [Us] rated supply voltage | 24 V DC |
| Current Consumption | 56...127 mA |
| Supply voltage limits | 20.4…26.24 V DC |
| Communication Port Protocol | CANopen |
| Bus type | CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable; CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable |
Technical Data
| [Ui] rated insulation voltage | 690 V EN/IEC 60947-1; 690 V CSA C22.2 No 14; 690 V UL 508 |
|---|---|
| [Uimp] rated impulse withstand voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1; 0.8 kV communication circuit EN/IEC 60947-4-1; 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
| Short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Associated fuse rating | 4 A gG output; 0.5 A gG control circuit |
| Protection Type | Overload (long time); Thermal protection; Load fluctuation; Locked rotor; Overload; Thermal overload protection; Power factor variation; Phase unbalance; Reverse polarity protection; Earth-leakage protection; Phase failure |
| Network and machine diagnosis type | Phase fault and earth fault trip counters; Trip context information; Waiting time after overload tripping; Fault recording; Remaining operating time before overload tripping; Starting current and time; Motor control command recording; Event recording; Running hours counter/operating time; Trip history information |
| Logic input number | 6 |
| Input current | 7 mA |
| Current state 0 guaranteed | Logic input < 5 V <= 15 mA 5 ms |
| Current state 1 guaranteed | Logic input < 15 V 2...15 mA 15 ms |
| Maximum output switching frequency | 2 Hz |
| Load current | 5 A 250 V AC logic output; 5 A 30 V DC logic output |
| Permissible power | 480 VA AC-15), Ie = 2 A, 500000 cycles output); 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Maximum operating rate | 1800 cyc/h |
| Contacts type and composition | 1 NO + 1 NC fault signal; 3 NO |
| Metering type | Temperature; Imbalance current; Phase current I1, I2, I3 RMS; Earth-fault current; Average current Iavg |
| Measurement accuracy | 5...15 % earth fault current internal measurement; 1 % voltage 100...830 V); 3 % power factor; 5 % earth fault current external measurement; +/- 30 min/year internal clock; 0,02 Temperature; 1 % current; 5 % active and reactive power |
| Overvoltage category | III |
| Connection pitch | 0.20 in (5.08 mm) |
| Connections - terminals | Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) 24 AWG...14 AWG)flexible with cable end; Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) 24 AWG...14 AWG)flexible without cable end; Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) 24 AWG...14 AWG)flexible without cable end; Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) 24 AWG...14 AWG)solid without cable end; Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) 24 AWG...14 AWG)flexible with cable end; Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) 24 AWG...14 AWG)flexible without cable end; Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) 24 AWG...14 AWG)flexible without cable end; Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) 24 AWG...14 AWG)solid without cable end |
| Tightening torque | Control circuit: 4.4…5.3 lbf.in (0.5…0.6 N.m) flat screwdriver 0.1 in (3 mm) |
| Pollution degree | 3 |
| Electromagnetic compatibility | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2; Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3; Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4; Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4; Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11; Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6; Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5; Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5; Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5; Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5; Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5; Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5; Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 |
| Width | 3.6 in (91 mm) |
| Height | 2.4 in (61 mm) |
| Depth | 4.8 in (122.5 mm) |
| Net Weight | 1.17 lb(US) (0.53 kg) |
| Web services | Web server |
| Compatibility code | LTMR |
Environment & Certifications
| Standards | CSA C22.2 No 14; IEC 60947-4-1; EN 60947-4-1; IACS E10; UL 508 |
|---|---|
| Product Certifications | CSA; DNV; RINA; KERI; NOM; BV; CCC; EAC; ATEX; ABS; LROS (Lloyds register of shipping); C-tick; GL; UL; RMRoS |
| Protective treatment | 12 x 24 hour cycles EN/IEC 60068-2-30; 48 h EN/IEC 60070-2-11; TH EN/IEC 60068 |
| Fire resistance | 1202 °F (650 °C) EN/IEC 60695-2-12; 1760 °F (960 °C) UL 94 |
| Ambient air temperature for operation | -4…140 °F (-20…60 °C) |
| Ambient Air Temperature for Storage | -40…176 °F (-40…80 °C) |
| Operating altitude | <= 6561.68 ft (2000 m) without derating |
| Mechanical robustness | Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6; Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6; Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 |
| IP Degree of Protection | IP20 |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 2.8 in (7.0 cm) |
| Package 1 Width | 3.9 in (10.0 cm) |
| Package 1 Length | 5.3 in (13.5 cm) |
| Package weight(Lbs) | 18.1 oz (514.0 g) |
| Number of Units in Package 2 | 10 |
| Package 2 Height | 5.9 in (15.0 cm) |
| Package 2 Width | 11.8 in (30.0 cm) |
| Package 2 Length | 15.7 in (40.0 cm) |
| Package 2 Weight | 12.092 lb(US) (5.485 kg) |
| GTIN | 3389119404709 |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

LTMR27CBD
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.