METSEPM8144
Schneider Electric power quality meter, PowerLogic PM8000, Essential, transducer and remote display, 64MB, 128s/c.
إظهار المواصفات
Main Characteristics
| Range | PowerLogic |
|---|---|
| Product name | PowerLogic PM8000 |
| Product or Component Type | Power meter |
| Market segment | Buildings large building cost management: billing: sub feeder; Buildings small building network management: main incomer; Buildings medium building network management: main incomer; Buildings large building network management: main incomer; Buildings large building network management: sub feeder; Buildings multi-site network management: main incomer; Buildings multi-site network management: sub feeder; Data center small building network management: main incomer; Data center large building network management: sub feeder; Healthcare large building network management: main incomer; Healthcare multi-site network management: sub feeder; Industry network management: main incomer; Industry network management: sub feeder; Utility: sub feeder |
| Model type | Essential |
Technical Data
| Power quality analysis | EN 50160 2010 compliance report; IEEE 519 2014 compliance report; up to the 63rd harmonic; harmonic distortion; waveform capture; voltage sag and swell detection; programmablity (logic and math functions); IEC 62586 power quality monitoring |
|---|---|
| Device Application | WAGES metering; Power monitoring |
| Type of measurement | Current; Voltage per phase, rms; Frequency total; Active and reactive power total; Apparent power total; Power factor total; Active and reactive power per phase, rms; Apparent power per phase, rms; Power factor per phase, rms |
| Supply voltage | 90...415 V AC 45...65 Hz +/- 10 %; 110...415 V DC +/- 10 % |
| Network Frequency | 50 Hz; 60 Hz |
| Line Rated Current | 10 A; 5 A; 1 A |
| Poles description | 3P; 1P + N; 3P + N |
| Power Consumption in VA | 16 VA 230 V AC |
| Display Type | Remote LCD display |
| Display Resolution | 320 x 240 pixels QVGA |
| Sampling rate | 128 samples/cycle |
| Measurement current | 50…10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm); Current (impedance 0.3 mOhm) |
| Measurement voltage | 57…400 V AC 42...69 Hz between phase and neutral; 100…690 V AC 42...69 Hz between phases |
| Frequency measurement range | 42…69 Hz |
| Number of inputs | 3 digital 30 V AC; 3 digital 60 V DC |
| Measurement accuracy | Current +/- 0.1 %; Voltage +/- 0.1 %; Active energy +/- 0.2 % |
| Accuracy class | Class 0.2S active energy IEC 62053-22; Class 0.2 active energy ANSI C12.20; Class 0.2 active power IEC 61557-12; Class 0.5S reactive energy IEC 62053-24; Class 0.5 power factor IEC 61557-12; Class 0.2 voltage IEC 61557-12; Class 0.2 current IEC 61557-12 |
| Number of Outputs | 1 pulse |
| Information displayed | Voltage; Current; Frequency; Power; Energy consumption; Harmonic distortion |
| Communication port protocol | Modbus RTU 115 kbauds - 2-wire; ION 115 kbauds - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s; RSTP 801.1d 2004 |
| Communication port support | ETHERNET; Screw terminal block RS485 |
| Communication Network Type | IPv6 (internet protocol) |
| Data recording | Sequence of event recording; Event logs; Min/max of instantaneous values; Harmonics logs; Alarm logs; GPS synchronisation; Waveform logs; Data logs; Time stamping; Trending/forecasting; Sag and swell logs; 10 data recorders |
| Memory capacity | 64 MB |
| Web services | Customizable home page; File upload/download via FTP; File upload/download via SFTP; Web server; Alarm notification by e-mail; Viewing of captured waveform (FTP); Viewing of captured waveform (web); HTTPS server |
| Communication Service | SMTP e-mail notification; RSTP support; NTP time synchronization; DHCP; PTP time synchronization |
| Cybersecurity | Password protection; Syslog protocol support; Port hardening; Robust security logs; Enable/disable communication ports |
| Mounting Mode | Flush-mounted; Clip-on |
| Mounting support | DIN rail meter device; Framework remote display |
| Provided Equipment | Remote display |
| Installation category | III |
| Safety Construction | III400…690 V conforming to IEC 61010-1:ed. 3; III400…690 V conforming to EN 61010-1:ed. 3; III347…600 V conforming to UL 61010-1:ed. 3; III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Standards | IEC 62053-22; IEC 62053-24; IEC 62052-11; IEC 61557-12; IEEE 1588; IEC 62586-2; IEC 61326-1 |
| Product certifications | CE; CULus; N998 |
| Width | 3.6 in (90.5 mm) |
| Depth | 3.6 in (90.8 mm) |
| Height | 3.6 in (90.5 mm) |
| Net Weight | 18.6 oz (528 g) |
Environment & Certifications
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; Surge immunity test conforming to IEC 61000-4-5; Conducted RF disturbances (2...150 Hz) conforming to IEC 61000-4-6; Magnetic field at power frequency conforming to IEC 61000-4-8; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Immunity to impulse waves conforming to IEC 61000-4-12; Conducted and radiated emissions conforming to EN 55022; Conducted and radiated emissions conforming to EN 55011; Conducted and radiated emissions conforming to FCC part 15; Conducted and radiated emissions conforming to ICES-003; Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579; Surge withstand conforming to IEEE C37.90.1 |
|---|---|
| IP degree of protection | IP30 conforming to IEC 60529 |
| Relative humidity | 5…95 % |
| Ambient air temperature for operation | -13…158 °F (-25…70 °C) |
| Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
| Operating altitude | 9842.52 ft (3000 m) |
| Compatibility code | PM8244 |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 5.5 in (14.0 cm) |
| Package 1 Width | 5.5 in (14.0 cm) |
| Package 1 Length | 14.6 in (37.0 cm) |
| Package weight(Lbs) | 3.168 lb(US) (1.437 kg) |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 11.8 in (30 cm) |
| Package 2 Width | 11.8 in (30 cm) |
| Package 2 Length | 15.7 in (40 cm) |
| Package 2 Weight | 13.894 lb(US) (6.302 kg) |
| GTIN | 3606486874691 |
| Country of origin | CA |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

METSEPM8144
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.