NTSAMM0600
Schneider Electric analog Input/Output Module, 4 In, 2 Out, Group Isolated, Current, Voltage, 2 Wires, Modicon Edge I/O NTS.
إظهار المواصفات
Main Characteristics
| Range of Product | Modicon Edge I/O NTS |
|---|---|
| Product or Component Type | Analog output module |
| Mandatory accessory | NTSXBA0100H base; NTSXTB18_0_H terminal block |
| Product Compatibility | NTSN..... |
| Range Compatibility | Logic/motion controller - Modicon M262; Modicon M580; Third party |
| Device Application | Industrial Application |
| Analogue input number | 4 |
| Analogue output number | 2 |
| Operating Mode | Isochronous/Asynchronous |
Technical Data
| Analogue input type | Current +/- 20 mA; Current 0...20 mA; Current 4...20 mA; Voltage +/- 10 V; Voltage 0...10 V; Voltage +/- 5 V; Voltage 0...5 V; Voltage 1...5 V |
|---|---|
| Input wiring mode | 1 or 2 wires |
| Analogue input resolution | 15 bits + sign |
| Permitted overload on inputs | 30 V maximum voltage; 30 V at 50 mA maximum current |
| Input impedance | > 10 MOhm in voltage mode; 100 Ohm + internal current protector 10 Ohm typical |
| Sampling duration | 1.69 ms per module |
| Input protection type | Over current / miswiring protection per channel for current input; Over voltage / miswiring protection per channel for voltage input |
| Input diagnostic | Underflow error per channel; Overflow error per channel; Broken wire error per channel; Hardware error per channel |
| Analogue output type | Current 0...20 mA; Current 4...20 mA; Voltage +/- 10 V; Voltage 0...10 V; Voltage +/- 5 V; Voltage 0...5 V; Voltage 1...5 V |
| Output wiring mode | 2 wires |
| LSB value | 0.31 mV, +/- 10 V; 0.31 mV, 0...10 V; 0.16 mV, +/- 5 V; 0.16 mV, 0...5 V; 0.13 mV, 1...5 V; 0.61 µA, +/- 20 mA; 0.61 µA, 0...2 mA; 0.49 µA, 4...20 mA |
| Output protection type | 16 mA short circuit and 30V over voltage for voltage output; 30V over voltage for current output |
| Load impedance ohmic | 600 Ohm current; 1 kOhm voltage |
| Response time on output | 1.2 ms at 600 Ohm per module |
| HART tolerance | Yes |
| Type of Cable | Shielded cable |
| Temperature drift | ± 0.0057 % FS/ °C input; ± 0.0006 % FS/ °C output |
| Measurement error | <= 0.3 % FS 25 °C input; <= 0.5 % FS - 20…60 °C input; <= 0.3 % FS 25 °C output; <= 0.5 % FS - 20…60 °C output |
| Non-linearity | <= 0.01 % FS analog input analog output; <= 0.02 % FS analog output |
| Common mode rejection | 90 dB |
| Power supply type | Bus power from power supply bus (24 Vdc); Field power from power supply field (24 Vdc) |
| Rated operational voltage limits | 20.4...28.8 V DC |
| Typical current consumption | 37.4 mA 24 V DC on the Bus current; 28.3 mA 24 V DC on the internal field current minimum; 80.4 mA 24 V DC on the internal field current maximum |
| Power dissipation in W | 2.3 W maximum at 24 V DC |
| Maximum cable distance between devices | Shielded cable <656.2 ft (200 m) voltage inputs; Shielded cable <3280.8 ft (1000 m) current input; Shielded cable <656.2 ft (200 m) voltage output; Shielded cable <3280.8 ft (1000 m) current output |
| Isolation between group | 530 V AC |
| Isolation between channels and bus | 1500 V AC |
| Isolation between channels and field pwr | 1000 Vac for input; 1000 Vac for output |
| Isolation between field power and bus | 1500 V AC |
| Hot swapping fallback | Yes |
| Local signalling | 1 LED green module operating (RUN); 1 LED per channel green channel diagnostic; 1 LED red module error (ERR) |
| Housing Colour | Grey |
| Mounting support | base |
| Height | 3.9 in (100 mm) |
| Width | 0.6 in (15 mm) |
| Depth | 2.7 in (69 mm) |
| Net Weight | 0.106 lb(US) (0.048 kg) |
Environment & Certifications
| IP Degree of Protection | IP20 |
|---|---|
| Marking | CE; UKCA; CULus; RCM |
| Product certifications | CE; UKCA; CULus; RCM; Merchant Navy - EU RO MR (pending); EAC (pending); ATEX Zone 2 (pending); IECEx zone 2 (pending); CCC Ex zone 2 (pending) |
| Standards | EN/IEC 61131-2; EN 61010-2-201; UL 61010-2-201; IACS E10; EN/IEC 61000-6-5; EN/IEC 61850-3; EN/IEC 60079-0; EN 50155; EN 50121-4; EN 50121-5 |
| Directives | 2014/30/EU - electromagnetic compatibility; 2014/34/EU - ATEX directive; 2014/35/EU |
| Ambient air temperature for operation | -4…140 °F (-20…60 °C) |
| Ambient air temperature for storage | -40…185 °F (-40…85 °C) |
| Relative humidity | 5…95 % without condensation |
| Operating altitude | 0...6561.68 ft (0...2000 m); 2000...5000 m with derating |
| Pollution degree | 2 |
| Environmental characteristic | Gas resistant C3 and G2 |
| Vibration resistance | 1 g without accessory; 2 g with accessory |
| Shock resistance | 15 g 11 ms with and without accessory) |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 1.0 in (2.5 cm) |
| Package 1 Width | 3.3 in (8.3 cm) |
| Package 1 Length | 4.6 in (11.6 cm) |
| Package weight(Lbs) | 1.8 oz (50.4 g) |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 5.9 in (15 cm) |
| Package 2 Width | 5.9 in (15 cm) |
| Package 2 Length | 15.7 in (40 cm) |
| Package 2 Weight | 2.2170 lb(US) (1.0056 kg) |
| GTIN | 3606486876268 |
| Country of origin | ID |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

NTSAMM0600
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.