| Range of product | PowerLogic P5 |
|---|---|
| Product or component type | Protection and control relay |
| Relay application | Universal |
| Product reference | P5U20-AABA-CAAAA-BAEA |
| Mounting case size | 20TE |
| Device mounting | Flush |
| Mounting mode | Withdrawable |
| Power supply | 24...240 V DC; 100...230 V AC |
| Measuring inputs | : 1/5 A CT phase current 3; : CSH residual current 1 |
| Number of sensors | 0 temperature sensor(s) ; 0 arc sensor(s) |
| Number of Digital Inputs (DI) | 4 |
| Number of analogue inputs | 0 |
| Number of Digital Outputs (DO) | 3 DO; 1 watchdog |
| Number of analogue outputs | 0 |
| Communication ports | USB port 2 front |
| Communication protocols | - |
| Cybersecurity | Port hardening; Firmware signature; Client IP address filter; Secured communication with assciated tools; Security policy management; Role-based access control; Security log; LDAP; RADIUS based user authentication; IEC 62443-4-2 SL1 |
| Protection functions | Phase overcurrent 50/51; Earth fault overcurrent 50N/51N; Capacitor bank unbalance 51C; Broken conductor 46 I2/I1; Current unbalance 46 I2/I1; Cold load pick-up; Switch ON to fault (SOTF); H2 detection; H5 detection; Breaker failure 50BF; Recloser 79; Thermal overload protection 49; Phase undercurrent 37; Negative sequence overcurrent 46; Excessive starting time, locked rotor 48/51LR; Motor restart inhibition 66; Capacitor overvoltage 59C; Lockout relay 86; CT supervision 60; Programmable stages 99; Programmable logic; Programmable curve |
| Measurement functions | Current 3-phase; Current zero sequence; Current positive sequence; Current negative sequence; Current ratio of negative and positive; Frequency; Phasor diagram of currents or voltages; Current 2nd, 15th harmonics with THD |
| Control functions | Switchgear control and monitoring; Programmable switchgear interlocking; Local/remote control |
| Controllable switchgear devices | 6 controlled + 2 monitored objects |
| Number of setting groups | 4 |
| Monitoring functions | Trip circuit supervision 74; Circuit breaker monitoring; Relay self-monitoring |
| Logs and records | Event recording; Disturbance recording; Tripping context; Relay maintenance |
| Switchgear diagnosis type | CT supervision ANSI code: 60; Trip circuit supervision ANSI code: 74 |
| Connections - terminals | Screw (digital input/output); Ring lugs (analog inputs and outputs) |
Technical Data
| Software name | ESetup Easergy Pro: virtual simulation test |
|---|---|
| Display type | LCD 192 x 96 pixels |
| Number of key | 1 customizable |
| Local signalling | 4 x LED; 6 x LED tri-colour programmable |
| Height | 176 mm |
| Width | 102 mm |
| Depth | 219 mm |
| Net weight | 2.5 kg |
Environment & Certifications
| Climatic withstand | Exposure to cold conforming to IEC 60068-2-1; Exposure to dry heat conforming to IEC 60068-2-2; Exposure to damp heat in service conforming to IEC 60068-2-78; Exposure to damp heat in service conforming to IEC 60068-2-30; Temperature variation conforming to IEC 60068-2-14; Salt mist conforming to IEC 60068-2-52; Influence of corrosion/gas test 2 conforming to IEC 60068-2-60; Influence of corrosion/gas test 4 conforming to IEC 60068-2-60; Influence of corrosion/gas test 2 conforming to IEC 60721-3-3; Influence of corrosion/gas test 4 conforming to IEC 60721-3-3 |
|---|---|
| Mechanical robustness | Vibrations (level: class 2) conforming to IEC 60255-21-1; Vibrations conforming to GOST 17516.1; Vibrations conforming to IACS E10; Shocks (level: class 2) conforming to IEC 60255-21-2; Earthquakes (level: class 2) conforming to IEC 60255-21-3 |
| Electromagnetic compatibility | Emission tests class A conforming to CISPR 11; Emission tests class A conforming to CISPR 32; Emission tests conforming to IACS E10; EMC immunity class 4 conforming to IEC 61000-4-2; EMC immunity class 4 conforming to ANSI C37.90.3; EMC immunity level 3 conforming to IEC 61000-4-3; EMC immunity conforming to ANSI C37.90.2; EMC immunity conforming to GOST 32137; EMC immunity conforming to GOST 30804.4.3; EMC immunity conforming to IACS E10; EMC immunity level 5 conforming to IEC 61000-4-8; EMC immunity level 5 conforming to IEC 61000-4-9; EMC immunity level 5 conforming to IEC 61000-4-10; EMC immunity level 3 conforming to IEC 61000-4-6; EMC immunity level 3 conforming to IEC 61000-4-18; EMC immunity conforming to ANSI C37.90.1; EMC immunity conforming to IEC 61000-4-12; EMC immunity conforming to GOST 30804.4.12; EMC immunity level 4 conforming to IEC 61000-4-16; EMC immunity level 4 conforming to IEC 61000-4-4; EMC immunity level 4 conforming to IEC 61000-4-5 |
| Ambient air temperature for operation | -40…85 °C ( 16 h ) ; -40…70 °C ( 96 h ) |
| Ambient air temperature for storage | -40…85 °C |
| IP degree of protection | IP54 conforming to IEC 60529 |
| Maximum operating altitude | 2000 m |
| Protective treatment | Conformal coating conforming to IEC 60068-2-52:Kb/1; Conformal coating conforming to IEC 60068-2-60:Ke; Conformal coating conforming to IEC 60721-3-3:3C2 |
| Relative humidity | 0…93 % at 40 °C, without condensation, 56 days; 93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours |
Packaging & Logistics
| Number of Units in Package 1 | 1 |
|---|---|
| Package 1 Height | 30.0 cm |
| Package 1 Width | 30.0 cm |
| Package 1 Length | 40.0 cm |
| Package 1 Weight | 3.0 kg |
Warranty
| Warranty (in months) | 24 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

REL50302
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.