Main Characteristics
| Range of product | PowerLogic P3 |
|---|---|
| Product or component type | Protection relay |
| Relay application | Universal |
| Product reference | P3U30-6CAA2BCAA |
| Mounting case size | 30TE |
| Device mounting | Flush |
| Mounting mode | Flush mounting |
| Power supply | 48...230 V AC/DC |
| Measuring inputs | : 1/5 A CT phase current 3; : CSH residual current 1; : 100 V/110 V VT voltage 4 |
| Number of sensors | 0 temperature sensor(s) |
| Number of Digital Inputs (DI) | 16 |
| Number of analogue inputs | 0 |
| Number of Digital Outputs (DO) | 8 DO; 1 watchdog |
| Number of analogue outputs | 0 |
| Communication ports | USB port 1 front; RJ45 2 rear |
| Communication protocols | IEC 61850 ed. 1; IEC 61850 ed. 2; IEC 60870-5-101; DNP3 TCP; Modbus TCP; EtherNet/IP |
| Redundancy communication port protocol | RSTP; PRP |
| Cybersecurity | Password protection; Port hardening |
| Protection functions | Negative sequence overcurrent 47; Phase overcurrent 50/51; Directional phase overcurrent 67; Earth fault overcurrent 50N/51N; Directional earth fault 67N; Transient earth fault 67NI; Capacitor bank unbalance 51C; Broken conductor 46 I2/I1; Cold load pick-up 47; H2 detection 68H2; H5 detection 68H5; Breaker failure 50BF; Switch ON to fault (SOTF) 50BF; Directional active underpower 37P; Fault locator 21FL; Recloser 79; Phase undercurrent 37; Excessive starting time, locked rotor 48/51LR; Switch ON to fault (SOTF) 27P; Motor restart inhibition 66; Capacitor overvoltage 59C; Negative sequence overcurrent 46; Overvoltage 59; Undervoltage 27; Positive sequence undervoltage 27P; Earth fault overvoltage 59N; Vector shift 78V; Underfrequency 81/81N; Rate of change of frequency 81R; Synchro-check 25; Lockout relay 86; CT supervision 60; VT supervision 60; Programmable stages 99 8; Programmable curve |
| Arc flash protection | No |
| Measurement functions | Current 3-phase; Current zero sequence; Current positive sequence; Current negative sequence; Current ratio of negative and positive; Voltage phase to earth; Voltage phase to phase; Voltage zero sequence; Voltage positive sequence; Voltage negative sequence; Voltage ratio of negative and positive; Short circuit fault reactance 2nd, 15th harmonics with THD; Fault location current ratio of negative and positive; Short circuit fault reactance 3-phase; Earth fault reactance positive sequence; Frequency; Active power; RMS active power 3-phase; Reactive power ratio of negative and positive; RMS reactive power phase to earth; Fault location current positive sequence; Apparent power negative sequence; RMS apparent power; Active energy; Reactive energy; Cos φ; Earth fault reactance negative sequence; Tan φ; Power angle; Power factor; Voltage phasor diagram view; Frequency ratio of negative and positive; Current phasor diagram view; Current 2nd, 15th harmonics with THD; Voltage 2nd, 15th harmonics with THD; Condition monitoring CB wear; Voltage interruption phasor diagram view; Active power phase to phase; RMS active power zero sequence; Reactive power positive sequence; RMS reactive power negative sequence; Condition monitoring CB wear 2nd, 15th harmonics with THD |
| Control functions | Switchgear control and monitoring with I/O keys; Programmable switchgear interlocking; Local control on single-line diagram; Local control with I/O keys; Local/remote control; 2 function keys; Mobile application with Easergy SmartApp; Web-server; Programmable logic |
| Controllable switchgear devices | 4 controlled + 8 displayed |
| Number of setting groups | 4 |
| Monitoring functions | Trip circuit supervision 74; Circuit breaker monitoring; Relay self-monitoring |
| Logs and records | Event recording; Disturbance recording; Tripping context |
| Switchgear diagnosis type | CT supervision; Trip circuit supervision ANSI code: TCS |
| Connections - terminals | Screw removable (digital input/output); Ring lugs removable (current transformer); Pin removable (voltage transformer) |
Technical Data
| Operating threshold | 110 V AC/DC |
|---|---|
| Time synchronisation protocol | SNTP |
| Software name | ESetup Easergy Pro: virtual simulation test; Easergy SmartApp |
| Web server | Embedded HTTP server |
| Display type | LCD 128 x 64 pixels with single line diagram |
| Number of key | 2 customizable |
| Local signalling | 4 LEDs; 8 LEDs programmable |
| Height | 169.5 mm |
| Width | 170 mm |
| Depth | 205 mm |
| Net weight | 2.5 kg maximum |
Environment & Certifications
| Climatic withstand | Exposure to dry heat Bd tests conforming to EN/IEC 60068-2-2; Exposure to cold Ad tests conforming to EN/IEC 60068-2-1; Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30; Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78 |
|---|---|
| Mechanical robustness | Vibrations (level: class II) conforming to IEC 60255-21-1; Vibrations: Fc conforming to IEC 60068-2-6; Shocks (level: class II) conforming to IEC 60255-21-2; Shocks: Ea conforming to IEC 60068-2-27; Seismic tests method A (level: class II) conforming to IEC 60255-21-3 |
| Electromagnetic compatibility | Emission tests conforming to IEC/EN 60255-26 ed. 3; Emission tests conforming to CISPR 11; Emission tests conforming to CISPR 22; EMC immunity conforming to IEC/EN 60255-26 ed. 3; EMC immunity conforming to EN/IEC 61000-4-18; EMC immunity conforming to IEC 60255-22-1; EMC immunity level 4 conforming to EN/IEC 61000-4-2; EMC immunity conforming to IEC 60255-22-2; EMC immunity level 3 conforming to EN/IEC 61000-4-3; EMC immunity conforming to IEC 60255-22-3; EMC immunity level 4 conforming to EN/IEC 61000-4-4; EMC immunity conforming to IEC 60255-22-4; EMC immunity level 3 conforming to EN/IEC 61000-4-5; EMC immunity conforming to IEC 60255-22-5; EMC immunity level 3 conforming to EN/IEC 61000-4-6; EMC immunity conforming to IEC 60255-22-6; EMC immunity conforming to EN/IEC 61000-4-8; EMC immunity level 5 conforming to EN/IEC 61000-4-9; EMC immunity conforming to EN/IEC 61000-4-29; EMC immunity conforming to EN/IEC 61000-4-11; EMC immunity conforming to EN/IEC 61000-4-17; EMC immunity conforming to IEC 60255-27; EMC immunity class III conforming to IEC 60255-5; EMC immunity conforming to EN/IEC 60255-1 |
| Ambient air temperature for operation | -40…65 °C |
| Ambient air temperature for storage | -40…70 °C |
| IP degree of protection | IP54 front |
| Maximum operating altitude | 2000 m |
| Protective treatment | Conformal coating |
| Relative humidity | 0…95 %, without condensation |
Packaging & Logistics
| Number of Units in Package 1 | 1 |
|---|---|
| Package 1 Height | 29.0 cm |
| Package 1 Width | 30.0 cm |
| Package 1 Length | 40.0 cm |
| Package 1 Weight | 3.51 kg |
Warranty
| Warranty (in months) | 24 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

REL52093
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.