RM4JA01B
Schneider Electric Harmony Relay current measurement relay RM4-J, range 3..1000 mA, 24 V.
إظهار المواصفات
Main Characteristics
| Lifecycle status | Discontinued by the manufacturer |
|---|---|
| Range of Product | Harmony Relay |
| Relay Type | Current measurement relay |
| Product or Component Type | Industrial measurement and control relays |
| Relay name | RM4J |
| Relay monitored parameters | Overcurrent detection |
| Contacts type and composition | 1 C/O |
Technical Data
| Maximum power consumption in VA | 2 VA AC |
|---|---|
| Measurement range | 0.3...30 mA current AC 50/60 Hz; 0.3...30 mA current DC; 10...100 mA current AC 50/60 Hz; 10...100 mA current DC; 100...1000 mA current AC 50/60 Hz; 100...1000 mA current DC |
| Maximum measuring cycle | 80 ms |
| Hysteresis | 5…30 % adjustable current threshold setting |
| Setting accuracy of the switching threshold | +/-5 % |
| Switching threshold drift | <= 0.06 % per degree centigrade depending permissible ambient air temperature; <= 0.5 % within the supply voltage range (0.85...1.1 Un) |
| Time delay type | Without |
| Setting accuracy of time delay | 10 P |
| Output contacts | 1 C/O |
| Maximum switching voltage | 440 V AC |
| Mechanical durability | 30000000 cycles |
| Operating voltage tolerance | 0.85...1.1 Uc |
| Internal input resistance | 33 Ohm; 10 Ohm; 1 Ohm |
| Permissible continuous overload | 0.15 A; 0.05 A; 1.5 A |
| Permissible non repetitive overload | 5 A; 0.2 A; 0.5 A |
| Supply disconnection value | > 0.1 Uc |
| [Ith] conventional free air thermal current | 8 A |
| [Ie] rated operational current | 2 A 24 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991; 2 A 24 V DC-13 158 °F (70 °C) VDE 0660; 3 A 115 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991; 3 A 115 V AC-15 158 °F (70 °C) VDE 0660; 3 A 24 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991; 3 A 24 V AC-15 158 °F (70 °C) VDE 0660; 3 A 250 V AC-15 158 °F (70 °C) IEC 60947-5-1/1991; 3 A 250 V AC-15 158 °F (70 °C) VDE 0660; 0.1 A 250 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991; 0.1 A 250 V DC-13 158 °F (70 °C) VDE 0660; 0.3 A 115 V DC-13 158 °F (70 °C) IEC 60947-5-1/1991; 0.3 A 115 V DC-13 158 °F (70 °C) VDE 0660 |
| Switching capacity in mA | 10 mA 12 V |
| Switching voltage | 250 V AC |
| Contacts material | 90/10 silver nickel contacts |
| Number of cables | 2 |
| Terminals description ISO n°1 | (C-B1-B2-B3)CO; (15-16-18)OC; (A1-A2)CO |
| Output relay state | Tripped if V measured > V set; Tripped if A measured > A set |
| 9 mm pitches | 2.5 |
Environment & Certifications
| Electromagnetic compatibility | Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2; Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 |
|---|---|
| Standards | IEC 60255-6 |
| Product Certifications | GL; CSA; UL |
| Marking | CE : LVD 73/23/EEC; CE : EMC 89/336/EEC |
| Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
| Ambient air temperature for operation | -4…149 °F (-20…65 °C) |
| Relative humidity | 15…85 % IEC 60721-3-3 |
| IP degree of protection | IP20 IEC 60529 terminals); IP50 IEC 60529 casing) |
| Pollution degree | 3 IEC 60664-1 |
| Overvoltage category | III conforming to IEC 60664-1 |
| Dielectric test voltage | 2.5 kV |
| [Ui] rated insulation voltage | 500 V IEC |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 2 x 1.5 mm²flexible with cable end; Screw terminals, 2 x 2.5 mm²flexible without cable end |
| Tightening torque | 5.3…9.7 lbf.in (0.6…1.1 N.m) |
| Height | 3.07 in (78 mm) |
| Width | 0.9 in (23 mm) |
| Depth | 3.1 in (80 mm) |
| Net Weight | 0.379 lb(US) (0.172 kg) |
| Environmental characteristic | 3K3 |
| Shock resistance | 15 gn 11 ms IEC 60255-21-1 |
| Non-dissipating shock wave | 4.8 kV |
| Resistance to electrostatic discharge | 6 kV contact IEC 61000-4-2 level 3; 8 kV air IEC 61000-4-2 level 3 |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) IEC 61000-4-3 level 3 |
| Resistance to fast transients | 2 kV IEC 61000-4-4 level 3 |
| Protection against electric shocks | 2 kV level 3 IEC 61000-4-5 |
| Disturbance radiated/conducted | CISPR 11 group 1 - class A; CISPR 22 - class A |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 1.06 in (2.7 cm) |
| Package 1 Width | 3.2 in (8.2 cm) |
| Package 1 Length | 3.3 in (8.5 cm) |
| Package weight(Lbs) | 6.4 oz (182 g) |
| GTIN | 3389110332919 |
| Country of origin | ID |
Warranty
| Warranty (in months) | 18 |
|---|
يتناسب جيدًا مع
تسليم موثوق للمنتجات الصناعية في جميع أنحاء العالم.
تجربة خالية من المخاطر لمدة 90 يومًا
ضمان لمدة سنتين
شحن وإرجاع مجانيان

RM4JA01B
إذا كانت لديك أي أسئلة، فنحن نرحب باتصالك بنا في أي وقت. سنرد عليك في أقرب وقت ممكن، خلال 24 ساعة في أيام الأسبوع.
-
معلومات الشحن
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
دعم العملاء
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
الأسئلة الشائعة
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
-
اتصل بنا
استخدم هذا النص للإجابة على الأسئلة بأكبر قدر ممكن من التفصيل لعملائك.
الأسئلة الشائعة
يرجى قراءة صفحة الأسئلة الشائعة لمعرفة المزيد.
هل تقومون بتوريد منتجات أصلية؟
نحن نوفر منتجات الأتمتة الصناعية والكهربائية الأصلية من الشركات المصنعة الرائدة بما في ذلك سيمنز (Siemens) وإيه بي بي (ABB) وشنايدر إليكتريك (Schneider Electric) وفينكس كونتاكت (Phoenix Contact) وإيتون (Eaton). أصالة المنتجات وجودتها هي أولويتنا.
هل يمكنني طلب عرض أسعار؟
نعم. إذا لم يتم عرض الأسعار أو كنت بحاجة إلى عناصر متعددة، فما عليك سوى استخدام زر "طلب عرض أسعار" أو الاتصال بفريق المبيعات لدينا للحصول على عرض أسعار مخصص.
هل تشحنون دوليًا؟
نعم. نحن نوفر خدمة الشحن إلى جميع أنحاء العالم، ويمكننا توصيل المنتجات إلى العملاء في جميع أنحاء أوروبا والشرق الأوسط وآسيا ووجهات دولية أخرى.
هل يمكنك توفير قطع غيار قديمة أو يصعب العثور عليها؟
نعم. نحن متخصصون في توريد مكونات الأتمتة الصناعية التي توقف إنتاجها أو عفا عليها الزمن أو يصعب العثور عليها من خلال شبكة الموردين العالمية لدينا.
ما هي الصناعات التي تخدمونها؟
نحن ندعم العملاء في قطاعات الصناعة والنفط والغاز والطاقة والمرافق ومعالجة المياه والبنية التحتية والأتمتة الصناعية.