Schneider Electric variable speed drive, Altivar HVAC ATH600, ATH650, 11kW, 15hp, 380 to 480V, 3 phase, IP55, UL type 12.
Show Specifications
Main Characteristics
| Range of Product | Altivar HVAC ATH600 |
|---|---|
| Product Specific Application | HVAC |
| Product or Component Type | Variable speed drive |
| Variant | Standard version |
| Product destination | Asynchronous motors; Synchronous motors |
| Mounting Mode | Wall mount |
| IP Degree of Protection | IP55; Type 12 |
| Phase | 3 phase |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| Relative symmetric mains voltage tolerance | 10 % |
| Supply frequency | 50...60 Hz - 5...5 % |
| Relative symmetric network frequency tolerance | 5 % |
| Nominal output current | 22.5 A 380 V normal duty); 21 A 480 V normal duty); 16 A 380 V heavy duty); 14 A 480 V heavy duty) |
| Maximum transient current | 24.8 A 60 s normal duty); 24.0 A 60 s heavy duty) |
| Motor power kW | 11 kW normal duty; 7.5 kW heavy duty |
| Maximum Horse Power Rating | 15 hp normal duty; 10 hp heavy duty |
| Line current | 18.53 A 380 V normal duty); 16 A 480 V normal duty); 13 A 380 V heavy duty); 11 A 480 V heavy duty) |
| EMC filter | Class C2 EMC filter integrated |
| Safety Function | STO (safe torque off) |
| Safety level | SIL 3 IEC 61508; PL = e ISO 13849-1 |
| Cybersecurity function | True |
| Cybersecurity level and standard | Security level (SL) 1 IEC 62443-4-2 |
| Communication port protocol | Modbus serial; BACnet MS/TP |
| Option card | Communication module BACnet IP; Communication module PROFINET; Communication module Ethernet IP/Modbus TCP; Digital and analog I/O extension module; Output relay extension module |
Technical Data
| Discrete input number | 8 |
|---|---|
| Discrete input type | STOA, STOB safety input, 24 V DC; DI1...DI6 digital input, 24 V DC4.4 kOhm; DI5, DI6 programmable as pulse input 0…30 kHz, 24 V DC |
| Discrete input logic | Positive logic (source) DI1...DI6), = 11 V; Positive logic (source) STOA, STOB), = 11 V; Negative logic (sink) DI1...DI6), > 16 V, 2.5 V |
| Input compatibility | DI1...DI6 discrete input level 1 PLC IEC 61131-2; DI5, DI6 pulse input level 1 PLC IEC 65A-68; STOA, STOB discrete input level 1 PLC IEC 61131-2 |
| Supply | External supply for control circuit 24 V DC 19…30 V), <800 mA overload and short-circuit protection; Internal supply for digital inputs and STO 24 V DC 20.4…27 V), <200 mA overload and short-circuit protection; Internal supply for reference potentiometer 10.5 V DC +/- 5 %, <10 mA short-circuit |
| Analogue input number | 3 |
| Analogue input type | AI1 0...10 V DC 30 kOhm 12 bits; AI2 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 12 bits; AI3 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 12 bits; AI2, AI3 PTC/PT 100/PT 1000/KTY84 temperature probe |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2 0...10 V 470 Ohm 10 bits; Software-configurable current AQ1, AQ2 0...20 mA 10 bits |
| Accuracy | +/- 1.5 % AI1, AI2, AI3) for a temperature variation 60 °C; +/- 1 % AQ1, AQ2) for a temperature variation 60 °C |
| Linearity error | AI1, AI2, AI3 +/- 0.15 % of maximum value analog input; AQ1, AQ2 +/- 0.2 % analog output |
| Relay output number | 3 |
| Relay output type | Relay outputs R1A, R1B, R1C 1 NO 1 NC 100000 cycles; Relay outputs R2A, R2C 1 NO 100000 cycles; Relay outputs R3A, R3C 1 NO 100000 cycles |
| Sampling duration | 2 ms + 0...0.5 ms DI1...DI6 digital input; 5 ms + 0...1 ms DI5, DI6 pulse input; 5 ms + 0...1 ms AI1, AI2, AI3; 10 ms + 0...1 ms AQ1, AQ2; 5 ms +/- 0.5 ms R1, R2, R3 |
| Maximum switching current | Relay output R1, R2, R3 resistive load 3 A 250 V AC; Relay output R1, R2, R3 resistive load 3 A 30 V DC; Relay output R1, R2, R3 inductive load, cos phi = 0.4 0.7 ms 2 A 250 V AC; Relay output R1, R2, R3 inductive load, cos phi = 0.4 0.7 ms 2 A 30 V DC |
| Minimum switching current | Relay output R1, R2, R3 5 mA 24 V DC |
| Physical interface | 2-wire RS 485 |
| Connector Type | RJ45 and open style terminals |
| Method of access | Server Modbus RTU; Subordinate BACnet MS/TP |
| Transmission Rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps; 9.6, 19.2, 38.4, 76.8 kbit/s |
| Transmission frame | RTU; MS/TP |
| Number of addresses | 1…247; 1…127 |
| Data format | 8 bits, configurable odd, even or no parity; 8 bits, no parity, 1 stop |
| Type of polarization | 120 ohm termination or no impedance |
| Prospective line Isc | 22 kA |
| Output frequency | 0.4 kHz |
| Output voltage | <= power supply voltage |
| 4 quadrant operation possible | False |
| Asynchronous motor control profile | Voltage/frequency ratio, 5 points; Flux vector control with sensor, standard; Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor - Energy Saving; Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor |
| Acceleration and deceleration ramps | Acceleration/deceleration ramp adaptation; Linear; S, U or customized |
| Motor slip compensation | Adjustable; Automatic whatever the load; Can be suppressed; Not available with synchronous motors |
| Switching frequency | 6...16 kHz adjustable with derating factor |
| Nominal switching frequency | 6 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | False |
| Apparent power | 13.1 kVA normal duty); 9.1 kVA heavy duty) |
| Power loss static current independent | 26 W |
| Power dissipation in W | 296 W 6 kHz normal duty); 217 W 6 kHz heavy duty) |
| Standards | UL 61800-5-1; EN/IEC 61800-3; EN/IEC 61800-5-1; IEC 61000-3-12; IEC 60721-3; IEC 61508; IEC 13849-1; RoHS |
| Product certifications | CE; UKCA; UL; CULus; EAC; RCM; KCC; ATEX |
| Marking | CE; UKCA; CULus; EAC; RCM; ATEX; WEEE; ROHS; KCC |
| With safety function Safe torque off (STO) | True |
| Protection type | Thermal overload protection motor; Safe torque off motor; Motor phase loss motor; Against exceeding limit speed motor; Temperature protection drive; Overheating drive; Output overcurrent between motor phase and earth drive; Output overcurrent between motor phases drive; Short-circuit between motor phase and earth drive; Short-circuit between motor phases drive; DC Bus overvoltage drive; Line supply overvoltage drive; Line supply undervoltage drive; Input supply loss drive; Break on the control circuit drive |
| Width | 9.2 in (234 mm) |
| Height | 16.8 in (427 mm) |
| Depth | 10.5 in (266 mm) |
| Net Weight | 16.09 lb(US) (7.3 kg) |
| Function Available | Fire mode; Forced fire mode; Run permissive; PID controller; 3 additional PID; Damper control; Underload detection for broken belt; Scroll compressor management; Skipped frequencies; Catch on the fly; Power monitoring; Cybersecure firmware update |
Environment & Certifications
| Operating altitude | 3280.84 ft (1000 m) without derating; 3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m |
|---|---|
| Operating position | Vertical position |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3; Class 3S3 according to IEC 60721-3-3; Class 3B1 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 15 gn at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 1 gn at 13…200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Relative humidity | 5…95 % without condensation IEC 60068-2-3 |
| Noise level | 44 dB |
| Pollution degree | 2 |
| Ambient air temperature for operation | 5…104 °F (-15…40 °C) without derating; 104…122 °F (40…50 °C) with derating factor |
| Ambient Air Temperature for Storage | -40…158 °F (-40…70 °C) |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 10.1 in (25.7 cm) |
| Package 1 Width | 9.02 in (22.9 cm) |
| Package 1 Length | 18.7 in (47.4 cm) |
| Package weight(Lbs) | 14.1 lb(US) (6.4 kg) |
| GTIN | 3606487958253 |
| Country of origin | ID |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

ATH650D11N4
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.