
ATV61HU30Y
Schneider Electric Altivar 61 variable speed drive ATV61, 3kW / 690V, 3HP / 575V, IP20.
Show Specifications
Main Characteristics
| Lifecycle status | Discontinued by the manufacturer |
|---|---|
| Range of Product | Altivar 61 |
| Product or Component Type | Variable speed drive |
| Product Specific Application | Pumping and ventilation machine |
| Component name | ATV61 |
| Motor power kW | 2.2 kW, 3 phase 500 V; 3 kW, 3 phase 690 V |
| Maximum Horse Power Rating | 3 hp, 3 phase 575 V |
| Power supply voltage | 500...690 V - 15...10 % |
| Supply number of phases | 3 phase |
| Line current | 4.4 A 600 V 3 phase 2.2 kW / 3 hp; 5.2 A 500 V 3 phase 2.2 kW / 3 hp; 5.2 A 690 V 3 phase 2.2 kW / 3 hp |
| EMC filter | Level 3 EMC filter |
| Assembly style | With heat sink |
| Maximum prospective line Isc | 22 kA 3 phase |
| Maximum transient current | 5.4 A 60 s, 3 phase |
| Nominal switching frequency | 4 kHz |
| Switching frequency | 2.5...6 kHz adjustable; 4...6 kHz with derating factor |
| Asynchronous motor control | Flux vector control without sensor, standard; Voltage/frequency ratio, 5 points; Voltage/frequency ratio - Energy Saving, quadratic U/f; Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor, standard |
| Communication Port Protocol | Modbus; CANopen |
| Type of polarization | No impedance Modbus |
| Option card | Communication card APOGEE FLN; Communication card BACnet; Communication card CC-Link; Controller inside programmable card; Communication card DeviceNet; Communication card EtherNet/IP; Communication card Fipio; I/O extension card; Communication card Interbus-S; Communication card LonWorks; Communication card METASYS N2; Communication card Modbus Plus; Communication card Modbus TCP; Communication card Modbus/Uni-Telway; Multi-pump card; Communication card Profibus DP; Communication card Profibus DP V1 |
Technical Data
| Product destination | Asynchronous motors; Synchronous motors |
|---|---|
| Power supply voltage limits | 425…759 V |
| Power supply frequency | 50...60 Hz - 5...5 % |
| Power supply frequency limits | 47.5...63 Hz |
| Continuous output current | 3.9 A 4 kHz, 575 V - 3 phase; 4.5 A 4 kHz, 500 V - 3 phase; 4.5 A 4 kHz, 690 V - 3 phase |
| Output frequency | 0.1…500 Hz |
| Speed range | 1…100 in open-loop mode, without speed feedback |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback |
| Torque accuracy | +/- 15 % in open-loop mode, without speed feedback |
| Transient overtorque | 130 % of nominal motor torque +/- 10 % 60 s |
| Braking torque | <= 125 % with braking resistor; 30 % without braking resistor |
| Regulation loop | Frequency PI regulator |
| Motor slip compensation | Automatic whatever the load; Adjustable; Not available in voltage/frequency ratio (2 or 5 points); Can be suppressed |
| Diagnostic | 1 LED (red) for drive voltage |
| Output voltage | <= power supply voltage |
| Electrical isolation | Between power and control terminals |
| Type of cable for mounting in an enclosure | With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC; With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC; Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC; Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR |
| Electrical connection | Terminal 2.5 mm² / 14 AWG AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); Terminal 50 mm² / 1/0 AWG L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Tightening torque | 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); 106.2 lbf.in (12 N.m), 102.2 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Supply | Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC, +/- 5 %, <10 mA overload and short-circuit protection; Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection; External supply 24 V DC 19…30 V) |
| Analogue input number | 2 |
| Analogue input type | AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign; AI2 software-configurable current 0...20 mA 242 Ohm 11 bits; AI2 software-configurable voltage 0...10 V DC 24 V max 30000 Ohm 11 bits |
| Sampling time | 2 ms +/- 0.5 ms AI1-/Al1+) - analog input; 2 ms +/- 0.5 ms Al2) - analog input; 2 ms +/- 0.5 ms AO1) - analog output; 2 ms +/- 0.5 ms LI1...LI5) - discrete input; 2 ms +/- 0.5 ms LI6)if configured as logic input - discrete input |
| Absolute accuracy precision | +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C; +/- 0.6 % AI2) for a temperature variation 60 °C; +/- 1 % AO1) for a temperature variation 60 °C |
| Linearity error | +/- 0.15 % of maximum value AI1-/Al1+); +/- 0.15 % of maximum value AI2); +/- 0.2 % AO1) |
| Analogue output number | 1 |
| Analogue output type | AO1 software-configurable current 0...20 mA 500 Ohm 10 bits; AO1 software-configurable voltage 0...10 V DC 470 Ohm 10 bits; AO1 software-configurable logic output 10 V, 20 mA |
| Discrete output number | 2 |
| Discrete output type | Configurable relay logic R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic R2A, R2B) NO - 100000 cycles |
| Maximum response time | <= 100 ms in STO (Safe Torque Off); R1A, R1B, R1C <= 7 ms +/- 0.5 ms; R2A, R2B <= 7 ms +/- 0.5 ms |
| Minimum switching current | 3 mA 24 V DC configurable relay logic |
| Maximum switching current | R1, R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms; R1, R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms; R1, R2 5 A 250 V AC resistive, cos phi = 1 0 ms; R1, R2 5 A 30 V DC resistive, cos phi = 1 0 ms |
| Discrete input number | 7 |
| Discrete input type | Programmable LI1...LI5) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm; Switch-configurable LI6) 24 V DC <= 30 V)level 1 PLC - 3500 Ohm; Switch-configurable PTC probe LI6)0…6 - 1500 Ohm; Safety input PWR) 24 V DC <= 30 V) - 1500 Ohm |
| Discrete input logic | Negative logic (sink) LI1...LI5), > 16 V, 11 V; Negative logic (sink) LI6)if configured as logic input, > 16 V, 11 V |
| Acceleration and deceleration ramps | Automatic adaptation of ramp if braking capacity exceeded, by using resistor; S, U or customized; Linear adjustable separately from 0.01 to 9000 s |
| Braking to standstill | By DC injection |
| Protection type | Against exceeding limit speed drive; Against input phase loss drive; Break on the control circuit drive; Input phase breaks drive; Line supply overvoltage drive; Line supply undervoltage drive; Overcurrent between output phases and earth drive; Overheating protection drive; Overvoltages on the DC bus drive; Power removal drive; Short-circuit between motor phases drive; Thermal protection drive; Motor phase break motor; Power removal motor; Thermal protection motor |
| Insulation resistance | > 1 mOhm 500 V DC for 1 minute to earth |
| Frequency resolution | Analog input 0.024/50 Hz; Display unit 0.1 Hz |
| Connector type | 1 RJ45 on front face)Modbus; 1 RJ45 on terminal)Modbus; Male SUB-D 9 on RJ45CANopen |
| Physical interface | 2-wire RS 485 Modbus |
| Transmission frame | RTU Modbus |
| Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal; 9600 bps, 19200 bps Modbus on front face; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen |
| Data format | 8 bits, 1 stop, even parity Modbus on front face; 8 bits, odd even or no configurable parity Modbus on terminal |
| Number of addresses | 1…127 CANopen; 1…247 Modbus |
| Method of access | Slave CANopen |
| Marking | CE |
| Operating position | Vertical +/- 10 degree |
| Net Weight | 66.1 lb(US) (30 kg) |
| Width | 9.4 in (240 mm) |
| Height | 16.5 in (420 mm) |
| Depth | 9.3 in (236 mm) |
Environment & Certifications
| Noise level | 59.9 dB 86/188/EEC |
|---|---|
| Dielectric strength | 3110 V DC between earth and power terminals; 5345 V DC between control and power terminals |
| Electromagnetic compatibility | Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Standards | IEC 60721-3-3 class 3C2; IEC 61800-3 environments 1 category C3; IEC 61800-5-1; IEC 61800-3; IEC 61800-3 environments 2 category C3; UL Type 1; EN 55011 class A group 2 |
| Product Certifications | CSA; UL; NOM 117; GOST; DNV; C-tick |
| Pollution degree | 3 IEC 61800-5-1; 3 UL 840 |
| Degree of proctection | IP20 on upper part without blanking plate on cover IEC 60529; IP20 on upper part without blanking plate on cover IEC 61800-5-1; IP21 IEC 60529; IP21 IEC 61800-5-1; IP41 on upper part IEC 60529; IP41 on upper part IEC 61800-5-1; IP54 on lower part IEC 60529; IP54 on lower part IEC 61800-5-1 |
| Vibration resistance | 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
| Relative humidity | 5…95 % without condensation IEC 60068-2-3; 5…95 % without dripping water IEC 60068-2-3 |
| Ambient air temperature for operation | 14…122 °F (-10…50 °C) (without derating); 122…140 °F (50…60 °C) (with derating factor) |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Operating altitude | <= 3280.84 ft (1000 m) without derating; 3280.84...7414.7 ft (1000...2260 m) with current derating 1 % per 100 m |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 15.7 in (40.0 cm) |
| Package 1 Width | 15.7 in (40.0 cm) |
| Package 1 Length | 23.6 in (60.0 cm) |
| Package weight(Lbs) | 70.5 lb(US) (32.0 kg) |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 30.3 in (77.0 cm) |
| Package 2 Width | 23.6 in (60.0 cm) |
| Package 2 Length | 31.5 in (80.0 cm) |
| Package 2 Weight | 160.9 lb(US) (73.0 kg) |
| GTIN | 3389119214650 |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

ATV61HU30Y
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.