ATV660C35T4X1
Schneider Electric variable speed drive, Altivar Process ATV600, ATV660 Compact Drive System, 400/315 kW, 480 V, CE, IP23.
Show Specifications
Main Characteristics
| Range of product | Altivar Process ATV600 |
|---|---|
| Product specific application | Process and utilities |
| Product or component type | Variable speed drive |
| Product destination | Asynchronous motors; Synchronous motors |
| Provided equipment | Enclosure PanelSeT SFN; Graphical operating panel in the enclosure door; Frequency inverter; Main switch; Line choke; Terminal block main supply; Terminal block motor |
| Colour of enclosure | Light grey (RAL 7035) |
| IP degree of protection | IP23 conforming to IEC 61800-5-1 |
| Communication port protocol | EtherNet/IP; Modbus TCP; Modbus serial |
| Type of cooling | Forced convection |
| Supply frequency | 50/60 Hz +/-5 % |
| [Us] rated supply voltage | 480 V +/- 10 % |
| Network number of phases | 3 phases |
| Output voltage | <= power supply voltage |
| Permissible temporary current boost | 1.1 x In during 60 s (normal duty); 1.5 x In during 60 s (heavy duty) |
| Speed drive output frequency | 0.1…500 Hz |
| Continuous output current | 660 A at 2.5 kHz for normal duty; 520 A at 2.5 kHz for heavy duty |
| Energy efficiency ratio | 0.98 |
| Power dissipation in W | 8530 W, total (normal duty); 6410 W, total (heavy duty); 930 W, control part (normal duty); 650 W, control part (heavy duty) |
| Volume of cooling air | 1740 m3/h for power; 280 m3/h for control |
| Noise level | 71 dB conforming to 86/188/EEC - physical agents (noise) directive |
| Motor power kW | 400 kW for normal duty; 315 kW for heavy duty |
| Prospective line Isc | 50 kA for 100 ms |
| Motor recommanded cable cross section | 3 x (3 x 150 mm²) (normal duty); 4 x (3 x 95 mm²) (normal duty); 2 x (3 x 185 mm²) (heavy duty); 3 x (3 x 120 mm²) (heavy duty) |
| Option card | Slot A: communication module, Profibus DP V1; Slot A: communication module, PROFINET; Slot A: communication module, DeviceNet; Slot A: communication module, Modbus TCP/EtherNet/IP; Slot A: communication module, CANopen daisy chain RJ45; Slot A: communication module, CANopen SUB-D 9; Slot A: communication module, CANopen screw terminals; Slot A/slot B: digital and analog I/O extension module; Slot A/slot B: output relay extension module |
| Safety function | STO (safe torque off), level SIL 3 for <= 100 ms |
| EMC filter | Integrated conforming to IEC 61800-3, category C3, shielded cable with 150 m; Integrated conforming to IEC 61800-3, category C4, unshielded cable with 250 m |
Technical Data
| Discrete input number | 8 |
|---|---|
| Protection type | Motor: thermal protection; Motor: safe torque off; Motor: motor phase break; Drive: thermal protection; Drive: safe torque off; Drive: overheating; Drive: overcurrent (between output phases and earth); Drive: overload (output); Drive: short-circuit protection; Drive: motor phase break; Drive: overvoltage (DC bus); Drive: line supply overvoltage; Drive: line supply undervoltage; Drive: line supply phase loss; Drive: overspeed; Drive: break on the control circuit; Drive: short-circuit protection with semi-conductor fuse (main supply); Drive: fan monitoring |
| Discrete input type | DI1...DI6 programmable, 24 V DC ( 2.2 kOhm |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.012/50 Hz |
| Connector type | RJ45 (on the control block) for Modbus serial; RJ45 (on the control block) for Ethernet IP/Modbus TCP |
| Discrete input logic | Positive logic (source) (DI1...DI6), 11 V (state 1); Negative logic (sink) (DI1...DI6), > 16 V (state 0), 2.5 V (state 1); Positive logic (source) (STOA, STOB), 11 V (state 1) |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Transmission frame | RTU for Modbus serial |
| Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
| Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
| Type of polarization | No impedance for Modbus serial |
| Analogue input number | 3 |
| Number of addresses | 1…247 for Modbus serial |
| Supply | External supply for digital inputs: 24 V DC (10…30 V), <1.25 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection; Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Local signalling | LCD display unit front door operation function, status and configuration |
| Input compatibility | DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2; DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Analogue output number | 2 |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI4) - discrete input; 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Isolation | Between power and control terminals |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Method of access | Slave Modbus TCP |
| Asynchronous motor control profile | Variable torque standard; Constant torque standard; Optimized torque mode |
| Synchronous motor control profile | Permanent magnet motor |
| Acceleration and deceleration ramps | S, U or customized; Linear adjustable separately from 0.01 to 9000 s |
| Motor slip compensation | Automatic whatever the load; Adjustable; Not available in permanent magnet motor law; Can be suppressed |
| Switching frequency | 2...8 kHz adjustable with derating factor |
| Nominal switching frequency | 2.5 kHz |
| Braking to standstill | By DC injection |
| Line current | 572 A at 480 V (normal duty); 456 A at 480 V (heavy duty) |
| Apparent power | 475 kVA at 480 V (normal duty); 379 kVA at 480 V (heavy duty) |
| Maximum transient current | 726 A during 60 s per 10 min (normal duty); 780 A during 60 s per 10 min (heavy duty) |
| Short-circuit protection | Internal: 315 A 3 aR fuse; Upstream: 800 A gG fuse (normal duty); Upstream: 630 A gG fuse (heavy duty) |
| Electrical connection | Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control; M12 bar for main supply; M12 bar for motor |
| Cable entry | Bottom |
| Width | 800 mm |
| Height | 2150 mm |
| Depth | 664 mm |
| Net weight | 650 kg |
Environment & Certifications
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
|---|---|
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6; 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6; 3M3 conforming to IEC 60721-3-3 |
| Shock resistance | 4 gn for 11 ms conforming to IEC 60068-2-27; 3M2 conforming to IEC 60721-3-3 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Operating altitude | < 1000 m without derating; 1000...2000 m with current derating 1 % per 100 m; 2000...3800 m with current derating 1 % per 100 m for TT earthing system; 2000...3800 m with current derating 1 % per 100 m for TN earthing system; 2000...3800 m with current derating 1 % per 100 m for IT earthing system; 3800...4800 m with current derating 1 % per 100 m for TT earthing system; 3800...4800 m with current derating 1 % per 100 m for TN earthing system |
| Environmental characteristic | Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3; Dust pollution resistance class 3S3 conforming to IEC 60721-3-3; Humidity resistant class 3K3 conforming to IEC 60721-3-3 |
| Operating position | Vertical +/- 10 degree |
| Product certifications | ATEX; EAC; C-Tick |
| Marking | CE |
| Standards | IEC 60204-1; IEC 61800-2; IEC 61800-3; IEC 61800-5-1 |
| Maximum THDI | <46 % full load conforming to IEC 61000-3-12 |
| Assembly style | In floor-standing enclosure compact version |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Overvoltage category | III |
| Ambient air temperature for operation | -10…0 °C without derating (with option enclosure heating); 0…40 °C without derating; 40…50 °C with derating factor |
| Ambient air temperature for storage | -25…70 °C |
Packaging & Logistics
| Number of Units in Package 1 | 1 |
|---|---|
| Package 1 Height | 236 cm |
| Package 1 Width | 1000 cm |
| Package 1 Length | 90 cm |
| Package 1 Weight | 680 kg |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

ATV660C35T4X1
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.