LC1D65ED
Schneider Electric TeSys Deca Advanced contactor, TeSys Deca,3P(3NO),AC-3/AC-3e 440V 65A,coil 36V DC, screw clamp terminals.
Show Specifications
Main Characteristics
| Lifecycle status | Discontinued by the manufacturer |
|---|---|
| Range | TeSys |
| Range of Product | TeSys Deca Advanced |
| Product or Component Type | Contactor |
| Contactor application | Resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4 |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz |
| [Ie] rated operational current | 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit; 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit; 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit |
| [Uc] control circuit voltage | 48 V DC |
Technical Data
| Motor power kW | 18.5 kW at 220/230 V AC 50/60 Hz (AC-3); 30 kW at 380/400 V AC 50/60 Hz (AC-3); 30 kW at 415 V AC 50/60 Hz (AC-3); 30 kW at 440 V AC 50/60 Hz (AC-3); 37 kW at 500 V AC 50/60 Hz (AC-3); 37 kW at 660/690 V AC 50/60 Hz (AC-3); 37 kW at 1000 V AC 50/60 Hz (AC-3); 18.5 kW at 220/230 V AC 50/60 Hz (AC-3e); 30 kW at 380/400 V AC 50/60 Hz (AC-3e); 30 kW at 415 V AC 50/60 Hz (AC-3e); 30 kW at 440 V AC 50/60 Hz (AC-3e); 37 kW at 500 V AC 50/60 Hz (AC-3e); 37 kW at 660/690 V AC 50/60 Hz (AC-3e); 37 kW at 1000 V AC 50/60 Hz (AC-3e); 11 kW at 400 V AC 50/60 Hz (AC-4) |
|---|---|
| Maximum Horse Power Rating | 10 hp at 230/240 V AC 60 Hz for 1 phase motors; 20 hp at 200/208 V AC 60 Hz for 3 phase motors; 20 hp at 230/240 V AC 60 Hz for 3 phase motors; 40 hp at 460/480 V AC 60 Hz for 3 phase motors; 50 hp at 575/600 V AC 60 Hz for 3 phase motors; 5 hp at 115 V AC 60 Hz for 1 phase motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 80 A (at 140 °F (60 °C)) for power circuit; 10 A (at 140 °F (60 °C)) for control circuit |
| Irms rated making capacity | 1000 A at 440 V DC for power circuit conforming to IEC 60947; 1000 A at 440 V for power circuit conforming to IEC 60947; 250 A DC for control circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Associated fuse rating | 125 A gG at <= 690 V coordination type 2 for power circuit; 160 A gG at <= 690 V coordination type 1 for power circuit conforming to IEC 60947-5-1; 125 A gG at <= 690 V coordination type 1 for power circuit; 10 A gG for control circuit conforming to IEC 60947-5-1 |
| Power dissipation per pole | 6.4 W AC-1; 4.2 W AC-3e; 4.2 W AC-3 |
| [Ui] rated insulation voltage | Control circuit 600 V UL; Power circuit 600 V CSA; Power circuit 600 V UL IEC 60947-1; Control circuit 690 V IEC 60947-1; Power circuit 690 V IEC 60947-1; Power circuit 1000 V CSA IEC 60947-4-1; Control circuit 600 V CSA |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1; B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 |
| Mechanical durability | 10 Mcycles |
| Control circuit type | DC wide range |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits | 0.75...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC; 1...1.25 Uc (140…158 °F (60…70 °C)):operational DC; 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC |
| Inrush power in W | 19 W 68 °F (20 °C)) |
| Hold-in power consumption in W | 22 W 68 °F (20 °C) |
| Rated operational power in W | 38 W 48 V DC-13 3000000 cycles - control circuit; 76 W 48 V DC-13 1000000 cycles - control circuit; 12 W 48 V DC-13 10000000 cycles - control circuit |
| Operating time | 50 ±15 % ms closing; 20 ±20 % ms opening |
| Time constant | 34 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid without cable end; Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: rigid; Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: rigid without cable end; Power circuit: screw clamp terminals 1 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…16 mm²) - cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.004…0.04 in² (2.5…25 mm²) - cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.004…0.02 in² (2.5…10 mm²) - cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid; Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid |
| Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2; Power circuit 44.3 lbf.in (5 N.m) screw terminal flat Ø 6 to Ø 8 mm; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal pozidriv No 2; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mirror contact 1 NC IEC 60947-4-1; Mechanically linked 1 NO + 1 NC IEC 60947-5-1 |
| Minimum switching voltage | 17 V for control circuit |
| Minimum switching current | 5 mA for control circuit |
| Insulation resistance | > 10 MOhm for control circuit |
| Non-overlap time | 1.5 ms on energisation between NC and NO contacts; 1.5 ms on de-energisation between NC and NO contacts |
| Mounting Support | Plate |
Environment & Certifications
| Standards | UL 60947-4-1; EN 60947-5-1; EN 60947-4-1; IEC 60947-5-1; CSA C22.2 No 14; IEC 60947-4-1 |
|---|---|
| Product Certifications | CCC; CSA; GOST; RINA; GL; DNV; LROS (Lloyds register of shipping); UL; UKCA |
| IP degree of protection | IP2X VDE 0106; IP2X IEC 60529 |
| Climatic withstand | IACS E10 exposure to damp heat |
| Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Shocks contactor closed 15 Gn for 11 ms) ; Vibrations contactor opened 2 Gn, 5...300 Hz) ; Vibrations contactor closed 4 Gn, 5...300 Hz) ; Shocks contactor opened 10 Gn for 11 ms) |
| Height | 5 in (127 mm) |
| Width | 3.3 in (85 mm) |
| Depth | 6.9 in (176 mm) |
| Net Weight | 4.817 lb(US) (2.185 kg) |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 7.362 in (18.700 cm) |
| Package 1 Width | 5.591 in (14.200 cm) |
| Package 1 Length | 3.465 in (8.800 cm) |
| Package weight(Lbs) | 4.833 lb(US) (2.192 kg) |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 5.9 in (15 cm) |
| Package 2 Width | 11.8 in (30 cm) |
| Package 2 Length | 15.7 in (40 cm) |
| Package 2 Weight | 10.238 lb(US) (4.644 kg) |
| Number of Units in Package 3 | 32 |
| Package 3 Height | 29.528 in (75.000 cm) |
| Package 3 Width | 31.496 in (80.000 cm) |
| Package 3 Length | 23.622 in (60.000 cm) |
| Package 3 Weight | 181.449 lb(US) (82.304 kg) |
| GTIN | 3389110436600 |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

LC1D65ED
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.