Schneider Electric reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC, 400 to 415VAC coil.
Show Specifications
Main Characteristics
| Lifecycle status | Discontinued by the manufacturer |
|---|---|
| Range | TeSys |
| Product name | TeSys K |
| Product or Component Type | Reversing contactor |
| Device Application | Control |
| Contactor application | Motor control; Resistive load |
| Utilisation category | AC-1; AC-4; AC-3 |
| Device presentation | Preassembled with reversing power busbar |
| Poles description | 3P |
| Power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit 690 V AC 50/60 Hz; Signalling circuit <= 690 V AC 50/60 Hz |
| [Ie] rated operational current | 20 A (at <122 °F (50 °C)) at <= 440 V AC AC-1 for power circuit; 16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit; 9 A at <= 440 V AC AC-3 for power circuit |
| Motor power kW | 2.2 kW 220...230 V AC 50/60 Hz; 4 kW 380...415 V AC 50/60 Hz; 4 kW 440 V AC 50/60 Hz; 4 kW 480 V AC 50/60 Hz; 4 kW 500...600 V AC 50/60 Hz; 4 kW 660...690 V AC 50/60 Hz |
| Control circuit type | AC 50/60 Hz |
| [Uc] control circuit voltage | 400...415 V AC 50/60 Hz |
| Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 122 °F (50 °C)) for power circuit; 10 A (at 122 °F (50 °C)) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110; 110 A AC for power circuit conforming to IEC 60947; 110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 415 V conforming to IEC 60947; 110 A at 440 V conforming to IEC 60947; 80 A at 500 V conforming to IEC 60947; 110 A at 220...230 V conforming to IEC 60947; 110 A at 380...400 V conforming to IEC 60947; 70 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 122 °F (50 °C) - 1 s for power circuit; 85 A 122 °F (50 °C) - 5 s for power circuit; 80 A 122 °F (50 °C) - 10 s for power circuit; 60 A 122 °F (50 °C) - 30 s for power circuit; 45 A 122 °F (50 °C) - 1 min for power circuit; 40 A 122 °F (50 °C) - 3 min for power circuit; 80 A - 1 s for signalling circuit; 90 A - 500 ms for signalling circuit; 110 A - 100 ms for signalling circuit; 20 A 122 °F (50 °C) - >= 15 min for power circuit |
| Associated fuse rating | 25 A gG at <= 440 V for power circuit; 25 A aM for power circuit; 10 A gG for signalling circuit conforming to IEC 60947; 10 A gG for signalling circuit conforming to VDE 0660 |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit 600 V UL 508; Power circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-4-1; Signalling circuit 690 V IEC 60947-5-1; Signalling circuit 600 V UL 508; Power circuit 600 V CSA C22.2 No 14; Signalling circuit 600 V CSA C22.2 No 14 |
| Electrical durability | 0.18 Mcycles 20 A AC-1 <= 440 V; 1.3 Mcycles 9 A AC-3 <= 440 V |
| Interlocking type | Mechanical |
| Mounting Support | Plate; Rail |
| Standards | EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1 |
| Product Certifications | CB Scheme; CCC; UL; CSA; EAC; CE; UKCA |
| Connections - terminals | screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid; screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end; screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end; screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid; screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end; screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end |
| Tightening torque | 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2; 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm |
| Operating time | 10...20 ms coil energisation and NO closing; 10...20 ms coil de-energisation and NO opening |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability | 5 Mcycles |
| Maximum operating rate | 3600 cyc/h |
Technical Data
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C)); Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C)) |
|---|---|
| Inrush power in VA | 30 VA (at 68 °F (20 °C)) |
| Hold-in power consumption in VA | 4.5 VA (at 68 °F (20 °C)) |
| Heat dissipation | 1.3 W |
| Auxiliary contacts type | Instantaneous 1 NC |
| Signalling circuit frequency | <= 400 Hz |
| Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit |
| Non overlap distance | 0.02 in (0.5 mm) |
| Insulation resistance | > 10 MOhm for signalling circuit |
Environment & Certifications
| IP degree of protection | IP20 VDE 0106 |
|---|---|
| Protective treatment | TC IEC 60068; TC DIN 50016 |
| Ambient Air Temperature for Operation | -13…122 °F (-25…50 °C) |
| Ambient Air Temperature for Storage | -58…176 °F (-50…80 °C) |
| Operating altitude | 6561.68 ft (2000 m) without derating |
| Flame retardance | V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102 |
| Mechanical robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27; Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27; Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6; Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 |
| Height | 2.3 in (58 mm) |
| Width | 3.5 in (90 mm) |
| Depth | 2.2 in (57 mm) |
| Net Weight | 0.86 lb(US) (0.39 kg) |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 2.4 in (6 cm) |
| Package 1 Width | 2.4 in (6.2 cm) |
| Package 1 Length | 3.6 in (9.2 cm) |
| Package weight(Lbs) | 13.05 oz (370 g) |
| GTIN | 3389110491968 |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

LC2K0901N7
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.