LUCMT1BL
Schneider Electric TeSys Ultra Multifunction control unit, TeSys U, 0.35-1.05A, 1P/3P motors, protection & diagnostic, class 5-30, coil 24V DC.
Show Specifications
Main Characteristics
| Lifecycle status | Discontinued by the manufacturer |
|---|---|
| Range | TeSys |
| Range of product | TeSys Ultra |
| Product or component type | Multifunction control unit |
| Device application | Motor control; Motor protection |
| Product specific application | Most sophisticated control and protection requirements, with display |
| Main function available | Overload, no-load running; Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Manual or automatic reset; Earth fault protection; Log function; Differentiation of thermal overload and magnetic fault; Protection function alarm; Monitoring function, indication of main motor parameters |
| Product compatibility | Power base LUTM |
| Network frequency | 40...60 Hz |
| Load type | 3-phase motor - cooling: self-cooled - setting factory setting; 3-phase motor - cooling: self-cooled, force cooled - setting settable; Single-phase motor - cooling: self-cooled, force cooled - setting settable |
| Utilisation category | AC-41; AC-44; AC-43 |
| Rated motor current adjustment range | 0.35…1.05 A |
| Thermal overload class | Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to IEC 60947-6-2; Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to UL 508 |
| Tripping threshold | 14.2 x Ir +/- 20 % |
| Phase failure sensitivity | Yes |
| [Uc] control circuit voltage | 24 V DC |
Technical Data
| Control circuit voltage limits | 20...28 V for DC circuit 24 V in operation; 14.5 V for DC circuit 24 V drop-out |
|---|---|
| Typical current consumption | 130 mA at 24 V DC I maximum while closing; 60 mA at 24 V DC I rms sealed |
| Heat dissipation | 2 W for control circuit |
| Operating time | 35 ms opening for control circuit; 70 ms closing for control circuit |
| Physical interface | RS485 multidrop - connector(s): RJ45 - location: front panel - communication protocol: Modbus RTU 19200 bit/s |
| Return time | <= 200 ms |
| Messages display capacity | 2 lines of 12 characters - display LCD - English - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - French - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - German - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - Italian - accuracy +/- 5 % - resolution 1 % of Ir; 2 lines of 12 characters - display LCD - Spanish - accuracy +/- 5 % - resolution 1 % of Ir |
| Reset | Automatic reset - setting: setting range; Manual - setting: factory setting; Manual - setting: setting range; Remote reset - setting: setting range |
| Time before reset | 1…1000 s - reset manual or automatic reset - setting settable; 120 s - reset manual - setting factory setting |
| User language | English - setting factory setting; English, French, German, Italian, Spanish - setting settable |
| Information displayed | Average current (factory setting); Average current (settable); Cause of last 5 faults (settable); Current in phase (settable); Earth leakage current (settable); Phase imbalance (settable); Thermal state of motor (settable) |
| Standards | EN 60947-6-2; IEC 60947-6-2; UL 508; CSA C22.2 No 14 |
| Product certifications | UL; CSA |
| [Ui] rated insulation voltage | 250 V conforming to IEC 60947-6-2; 250 V conforming to UL 60947-4-1; 250 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 60947-6-2 |
| Fixing mode | Plug-in (front face) |
| Width | 45 mm |
| Height | 66 mm |
| Depth | 60 mm |
| Net weight | 0.175 kg |
| Compatibility code | LUCM |
Environment & Certifications
| IP degree of protection | IP20 front panel and wired terminals conforming to IEC 60947-1; IP20 other faces conforming to IEC 60947-1; IP40 front panel outside connection zone conforming to IEC 60947-1 |
|---|---|
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 2000 m |
| Fire resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12; 650 °C conforming to IEC 60695-2-12 |
| Shock resistance | 10 gn power poles open conforming to IEC 60068-2-27; 15 gn power poles closed conforming to IEC 60068-2-27 |
| Vibration resistance | 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6; 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6 |
| Resistance to electrostatic discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2; 8 kV level 4 on contact conforming to IEC 61000-4-2 |
| Resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 |
| Resistance to fast transients | 2 kV class 3 serial link conforming to IEC 61000-4-4; 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 |
| Immunity to microbreaks | 3 ms |
| Immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
Packaging & Logistics
| Number of Units in Package 1 | 1 |
|---|---|
| Package 1 Height | 8.000 cm |
| Package 1 Width | 10.200 cm |
| Package 1 Length | 5.500 cm |
| Package 1 Weight | 171.900 g |
| Number of Units in Package 2 | 23 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 4.276 kg |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

LUCMT1BL
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.