METSEPM7212DUW
Schneider Electric power meter PowerLogic PM7212, class 0.5S, RS485, bluetooth LE, up to 31st Harmonic, 1DI/1DO, 2 tariff.
Show Specifications
Main Characteristics
| Range | PowerLogic |
|---|---|
| Product name | PowerLogic PM7000 |
| Product or component type | Power meter |
Technical Data
| Power quality analysis | up to the 31st harmonic; total harmonic distortion; total demand distortion |
|---|---|
| Metering type | Residual current I0 |
| Device application | Multi-tariff; Sub billing |
| Type of measurement | Voltage 3-phase; Current 3-phase; Power; Active power demand; Energy; Frequency; Power factor |
| [Us] rated supply voltage | 100...415 V AC 45...65 Hz; 125...250 V DC |
| Network frequency | 60 Hz; 50 Hz |
| [In] rated current | 5 A; 1 A |
| Type of network | 3P; 1P + N; 3P + N |
| Maximum power consumption in VA | 9.6 VA at 415 V AC; 8.6 VA at 230 V AC; 6.7 VA at 120 V AC |
| Ride-through time | 100 ms 120 V AC typical; 400 ms 230 V AC typical; 50 ms 125 V DC typical |
| Display type | Colour LCD |
| Display resolution | 320 x 240 pixels |
| Sampling rate | 128 samples/cycle |
| Analogue input type | Voltage (impedance 5 MOhm); Current (impedance <= 0.3 mOhm) |
| Measurement voltage | 20…400 V AC 47.5...63 Hz between phase and neutral; 35…690 V AC 47.5...63 Hz between phases; 35…760 V AC 47.5...63 Hz maximum |
| Frequency measurement range | 47.5…63 Hz |
| Number of inputs | 1 digital |
| Measurement accuracy | Active energy +/- 0.5 %; Reactive energy +/- 2 %; Active power +/- 0.5 %; Apparent power +/- 0.5 %; Reactive power +/- 2 %; Current +/- 0.5 %; Voltage +/- 0.5 %; Frequency +/- 0.05 %; Power factor +/- 0.005 |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22; Class 2S reactive energy conforming to IEC 62053-24; Class 0.5 active power conforming to IEC 61557-12; Class 0.5 apparent power conforming to IEC 61557-12; Class 2 reactive power conforming to IEC 61557-12; Class 0.5 current conforming to IEC 61557-12; Class 0.5 voltage conforming to IEC 61557-12; Class 0.5 phase unbalance conforming to IEC 61557-12; Class 2 harmonic distortion (I THD & U THD) conforming to IEC 61557-12; Class 2 individual voltage harmonic conforming to IEC 61557-12 |
| Number of outputs | 1 digital |
| Information displayed | Tariff (2) |
| Communication port protocol | Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none, insulation 2500 V; Bluetooth (BLE) |
| Communication port support | RS485 serial link |
| Data recording | Min/max of instantaneous values; Alarm logs; Data logs; Event logs; Maintenance logs; User-definable data logs; Time stamping |
| Memory capacity | 32 MB |
| Commissioning interface | PowerLogic Engineering Suite (PLES); EcoStruxure Power Commission desktop 3.x; EcoStruxure Power Device (EPD); EcoStruxure Power Commission Mobile 3.x |
| Mounting mode | Flush-mounted |
| Mounting support | Enclosure door |
| Type of installation | For indoor use in a stationary panel |
| Standards | IEC 62052-11:2020; IEC 62053-22:2020; IEC 62053-24:2020; IEC 61557-12:2022; EN 50470-1:2018; EN 50470-3:2022; ANSI C12.1:2022; ANSI C12.20:2022; GB/T 17215.211:2021; GB/T 17215.321:2021; IACS E10:2022; DNVGL-GC-0339:2021; IEC 62052-31:2015; BS EN 61010-2-30:2021; IEC 61010-1:2019; IEC 61010-2-030:2017; UL 61010-1:2023; UL 61010-2-30:2018; UL 2808:2020; UL 891:2019; UL 67:2018; BS EN 61326-1:2021; FCC CFR 47 part 15 class B; CISPR 11; CISPR 32; EN 55011:2022; EN 55032:2022; IEC 61326-1:2020; EN 62479:2010; EN 62311:2020; AS/NZS 4268:2021; GB/T 17215.324:2017; GB/T 18268.1:2010; BS EN 301 489-1:v2.2.3; BS EN 301 489-17:v3.2.4; ETSI EN 301 489-1:v2.2.3; ETSI EN 301 489-17:v3.2.4; EN 300-328:v2.2.2; MCMC MTSFB TC T007; NOM-208-SCFI-2016 |
| Product certifications | CE conforming to IEC 61010-1; CULus conforming to UL 61010-1 |
| Width | 96 mm |
| Depth | 72 mm |
| Height | 96 mm |
| Net weight | 577 g |
Environment & Certifications
| Electromagnetic compatibility | Limits for harmonic current emissions conforming to IEC 61000-3-2; Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3; Electrostatic discharge conforming to IEC 61000-4-2; Immunity to radiated fields conforming to IEC 61000-4-3; Immunity to fast transients conforming to IEC 61000-4-4; Immunity to surges conforming to IEC 61000-4-5; Immunity to conducted (150 kHz...80 MHz) conforming to IEC 61000-4-6; Immunity to magnetic fields conforming to IEC 61000-4-8; Voltage dips conforming to IEC 61000-4-11; Damped oscillating waves; Radiated emission class B conforming to FCC part 15; Radiated emission class B conforming to EN 55022; Conducted emission class B conforming to FCC part 15; Conducted emission class B conforming to EN 55022 |
|---|---|
| Overvoltage category | III; II |
| IP degree of protection | IP65 front: conforming to IEC 60529; IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % at 50 °C non condensing |
| Pollution degree | 2 |
| Ambient air temperature for operation | -25…70 °C meter; -20…70 °C display; -25…-20 °C (with reduced performance) display |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 2000 m CAT III; 3000 m CAT II |
Packaging & Logistics
| Number of Units in Package 1 | 1 |
|---|---|
| Package 1 Height | 14.2 cm |
| Package 1 Width | 12.3 cm |
| Package 1 Length | 13.5 cm |
| Package 1 Weight | 588 g |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.497 kg |
| Number of Units in Package 3 | 96 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 68.476 kg |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

METSEPM7212DUW
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.