METSEPM8340
Schneider Electric power quality meter, PowerLogic PM8000, Advanced, integrated display, 512MB, 512s/c.
Show Specifications
Main Characteristics
| Range | PowerLogic |
|---|---|
| Product name | PowerLogic PM8000 |
| Product or Component Type | Power meter |
| Market segment | Buildings large building cost management: billing: sub feeder; Buildings small building network management: main incomer; Buildings medium building network management: main incomer; Buildings large building network management: main incomer; Buildings large building network management: sub feeder; Buildings multi-site network management: main incomer; Buildings multi-site network management: sub feeder; Data center network management: main incomer; Data center small building network management: sub feeder; Healthcare large building network management: main incomer; Healthcare multi-site network management: sub feeder; Industry multi-site network management: main incomer; Industry network management: sub feeder; Utility network management: sub feeder |
| Model type | Advanced |
Technical Data
| Power quality analysis | EN 50160 2010 compliance report; IEEE 519 2014 compliance report; IEC 61000-4-30 class A power quality measurement; up to the 63rd harmonic; IEC 61000-4-15 harmonic distortion; EN 50160 2010 waveform capture; IEEE 519 2014 voltage sag and swell detection; programmablity (logic and math functions); IEC 62586 power quality monitoring; disturbance direction detection; IEC 61000-4-15 flicker; rapid voltage change |
|---|---|
| Device Application | Power monitoring; WAGES metering |
| Type of measurement | Current per phase, rms; Voltage; Frequency total; Active and reactive power total; Apparent power total; Power factor total; Active and reactive power per phase, rms; Apparent power per phase, rms; Power factor per phase, rms |
| Supply voltage | 90...415 V AC 45...65 Hz +/- 10 %; 110...415 V DC +/- 10 % |
| Network Frequency | 50 Hz; 60 Hz |
| Line Rated Current | 1 A; 5 A; 10 A |
| Poles description | 3P + N; 3P; 1P + N |
| Power Consumption in VA | 16 VA 230 V AC |
| Display Type | Colour TFT LCD |
| Display Resolution | 320 x 240 pixels QVGA |
| Sampling rate | 512 samples/cycle |
| Measurement current | 50…10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm); Current (impedance 0.3 mOhm) |
| Measurement voltage | 57…400 V AC 42...69 Hz between phase and neutral; 100…690 V AC 42...69 Hz between phases |
| Frequency measurement range | 42…69 Hz |
| Number of inputs | 3 digital 30 V AC; 3 digital 60 V DC |
| Measurement accuracy | Current +/- 0.1 %; Voltage +/- 0.1 %; Active energy +/- 0.2 % |
| Accuracy class | Class 0.2S active energy IEC 62053-22; Class 0.2 active energy ANSI C12.20; Class 0.2 active power IEC 61557-12; Class 0.5S reactive energy IEC 62053-24; Class 0.5 power factor IEC 61557-12; Class 0.2 voltage IEC 61557-12; Class 0.2 current IEC 61557-12 |
| Number of Outputs | 1 pulse |
| Information displayed | Voltage; Current; Frequency; Power; Energy consumption; Harmonic distortion |
| Communication port protocol | Modbus RTU 115 kbauds - 2-wire; ION 115 kbauds - 2-wire; DNP3; IEC 61850; Modbus TCP/IP; Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s; RSTP 801.1d 2004 |
| Communication port support | ETHERNET; Screw terminal block RS485 |
| Communication Network Type | IPv6 (internet protocol) |
| Data recording | Min/max of instantaneous values; Waveform logs; Sequence of event recording; Time stamping; Alarm logs; Trending/forecasting; Sag and swell logs; Harmonics logs; GPS synchronisation; Data logs; Event logs; 64 data recorders |
| Memory capacity | 512 MB |
| Web services | Customizable home page; File upload/download via FTP; File upload/download via SFTP; Web server; Alarm notification by e-mail; Viewing of captured waveform (FTP); Viewing of captured waveform (web); HTTPS server |
| Communication Service | SMTP e-mail notification; RSTP support; NTP time synchronization; DHCP; PTP time synchronization |
| Cybersecurity | Enable/disable communication ports; Password protection; Syslog protocol support; Robust security logs; Port hardening |
| Mounting Mode | Flush-mounted |
| Mounting support | Framework |
| Installation category | III |
| Safety Construction | III400…690 V conforming to IEC 61010-1:ed. 3; III400…690 V conforming to EN 61010-1:ed. 3; III347…600 V conforming to UL 61010-1:ed. 3; III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Standards | IEC 61557-12; IEC 62052-11; IEC 62053-24; IEC 62053-22; IEEE 1588; IEC 62586-2; IEC 61326-1 |
| Product certifications | CE; CULus; N998 |
| Width | 3.8 in (96 mm) |
| Depth | 3.05 in (77.5 mm) |
| Height | 3.8 in (96 mm) |
| Net Weight | 20.5 oz (581 g) |
Environment & Certifications
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test conforming to IEC 61000-4-4; Surge immunity test conforming to IEC 61000-4-5; Conducted RF disturbances conforming to IEC 61000-4-6; Magnetic field at power frequency conforming to IEC 61000-4-8; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11; Immunity to impulse waves conforming to IEC 61000-4-12; Conducted and radiated emissions (2...150 Hz) conforming to EN 55022; Conducted and radiated emissions conforming to EN 55011; Conducted and radiated emissions conforming to FCC part 15; Conducted and radiated emissions conforming to ICES-003; Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579; Surge withstand conforming to IEEE C37.90.1 |
|---|---|
| IP degree of protection | IP54 front: conforming to IEC 60529; IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % |
| Ambient air temperature for operation | -13…158 °F (-25…70 °C) |
| Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
| Operating altitude | 9842.52 ft (3000 m) |
| Compatibility code | PM8240 |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 5.472 in (13.900 cm) |
| Package 1 Width | 5.630 in (14.300 cm) |
| Package 1 Length | 7.441 in (18.900 cm) |
| Package weight(Lbs) | 30.265 oz (858.000 g) |
| GTIN | 3606486874752 |
| Country of origin | CA |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

METSEPM8340
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.