REL72505
Schneider Electric Protection and control relay, PowerLogic P7, motor standard, 5CT, 4VT, 40BI, 32BO, 110-250V, ethernet RJ45.
Show Specifications
Main Characteristics
| Range of Product | PowerLogic P7 |
|---|---|
| Product or Component Type | Protection and control relay |
| Relay application | Motor application and bay control |
| Product reference | P7 |
| Mounting case size | 40TE |
| Device mounting | Flush |
| Mounting Support | 19" rack |
| Mounting Mode | Flush mounting; Rack-mounted |
| Power supply | 110...250 V DC; 110...250 V AC 50/60 Hz |
| Measuring inputs | 4 CT 1/5 A; 1 CT 1 A; 4 VT |
| Number of Digital Inputs (DI) | 40 |
| Number of analogue inputs | 8 RTD optional |
| Number of Digital Outputs (DO) | 32; 1 watchdog |
| Type of temperature module connection | 2 twisted, type A, shielded wires (RS485) |
| Communication ports | 1 CAN port; 1 Ethernet TCP/IP; 2 SFP ports; 1 USB port; 1 COM serial link |
| Communication protocols | Modbus serial and TCP; DNP3 serial and TCP; IEC 61850 Ed 2.1; IEC 61869-9; IEC 61850-9-2 LE |
| Redundancy communication port protocol | HSR; PRP; RSTP; Failover |
| Cybersecurity | IEC 62443 SL2; LDAP; RADIUS based user authentication; Port hardening; Role-based access control; Secure boot; Security log; Syslog protocol support; Secured communication with assciated tools; Password protection; Firmware signature; Client IP address filter; Pre-login banner; Security policy management |
| Protection functions | Phase overcurrent 50/51; Ground fault protection 50N/51N; Sensitive earth fault overcurrent 50G/51G; Negative sequence overcurrent 46; Inrush detection 68; Phase undercurrent 37; Undervoltage 27; Overvoltage 59; Positive sequence undervoltage 47; Overfrequency 81O; Underfrequency 81U; High impedance differential 64REF; Motor differential 87M; Thermal overload for machines 49; Temperature monitoring (8 or 16 RTDs) 38/49T; Startup motoring 48; Locked rotor 51LR; Motor restart inhibition 66; Voltage check 47; Overspeed 12; Underspeed (2 set points) 14; Field loss (underimpedance) 40; Underimpedance 21; Out of step 78PS; CT supervision 60; VT supervision 60FL; Breaker failure 50 BF; Programmable logic |
| Measurement functions | Current 3-phase; RMS current 3-phase; Current sequence; Current 1-phase; RMS current 1-phase; Voltage 3-phase; RMS voltage 3-phase; Voltage sequence; Voltage 1-phase; RMS voltage 1-phase; Power maximum; Power factor minimum; Active power fundamental frequency; Apparent power fundamental frequency; Reactive power fundamental frequency; RMS active power 1-phase; RMS reactive power; RMS apparent power; Active power demand maximum; Active power demand minimum; Reactive power demand maximum; Reactive power demand minimum; Apparent power demand maximum; Apparent power demand minimum; RMS phase current demand maximum; RMS phase current demand minimum; Earth fault current external measurement |
| Control functions | Switchgear control and monitoring; Programmable switchgear interlocking; Local/remote control; Programmable logic; Remote control; Function keys |
| Controllable switchgear devices | 10 controlled objects |
| Number of setting groups | 8 |
| Monitoring functions | Circuit breaker monitoring; Switch monitoring; Relay self-monitoring; Trip circuit supervision 74; Event counters; Watchdog |
| Logs and records | Disturbance recording; Event recording; Fault recording; Operation log |
| Switchgear diagnosis type | CT/VT supervision 60; Auxiliary power supply monitoring; Cumulative breaking current; Number of operations; DC battery voltage monitoring |
| Connections - terminals | Screw type terminals (digital input/output); Ring terminal (analogue input) |
Technical Data
| Input power interruption | 100 ms; 200 ms |
|---|---|
| Maximum power consumption in W | 24 W typical |
| Operating threshold | 110 V DC; 220 V DC |
| Time synchronisation protocol | IRIG-B; SNTP; IEEE 1588 |
| Software name | PowerLogic Engineering Suite |
| Display type | Colour touchscreen 800 x 640 pixels |
| Display size | 7 inch |
| Information Displayed | Single line diagram; Menu-driven user interface |
| Control Button Type | 1 home physical key; 1 reset physical key; 12 customizable virtual function keys |
| Local signalling | 4 LEDs red/orange device status; 24 LEDs tri-colour programmable |
| Communication compatibility | DNP3; Modbus; IEC 61850 Ed 2.1 |
| Device connection | Connection to a PC USB; Extension port extension cable; Ethernet port RJ45; Serial port RS485 cable; SFP redundant Ethernet port fibre optic/RJ45 multi/single mode optional |
| Product Certifications | cUL Listed; UKCA; KETOP; CE; DNV |
| Height | 7.008 in (178 mm) |
| Width | 8.08 in (205.2 mm) |
| Depth | 11.1 in (282 mm) |
| Net weight | 19.4 lb(US) (8.8 kg) maximum |
Environment & Certifications
| Climatic withstand | Exposure to cold Ae IEC 60068-2-1; Exposure to dry heat Be IEC 60068-2-2; Exposure to damp heat in service Cab IEC 60068-2-78; Temperature variation Nb IEC 60068-2-14; Exposure to damp heat not in service Cab IEC 60068-2-30; Salt mist Kb/1 IEC 60068-2-52; Influence of corrosion/gas test 2 Ke IEC 60068-2-60; Influence of corrosion/gas test 4 Ke IEC 60068-2-60 |
|---|---|
| Mechanical robustness | Vibrations class 2) IEC 60255-21-1; Shocks class 2) IEC 60255-21-2; Shocks class 1) IEC 60255-21-2; Bumps class 1) IEC 60255-21-2; Seismic tests class 2) IEC 60255-21-3 |
| Electromagnetic compatibility | Electromagnetic immunity class A CISPR 11; Electromagnetic immunity class A CISPR 22; Electromagnetic immunity level 3 IEC 6100-4-3; Radiated radio-frequency electromagnetic field immunity test ANSI C37.90.2; Electrostatic discharge level 4 IEC 6100-4-2; Electrostatic discharge ANSI C37.90.3; Immunity to magnetic fields level 4 IEC 61000-4-8; Immunity to magnetic fields level 5 IEC 61000-4-9; Immunity to magnetic fields level 5 IEC 61000-4-10; Conducted RF disturbances level 3 IEC 61000-4-6; Fast transient bursts level 4 IEC 61000-4-4; Damped oscillatory wave level 3 IEC 61000-4-18; Damped oscillatory wave level 4 ANSI C37.90.1; Damped oscillatory wave level 3 IEC 61000-4-12; Conducted disturbance emission A IEC 61000-4-16; Surges level 4 IEC 61000-4-5 |
| Ambient air temperature for operation | -40…158 °F (-40…70 °C) 96 h ) |
| Ambient air temperature for storage | -40…185 °F (-40…85 °C) (96 h) |
| IP degree of protection | IP54 front IEC 60529; IP30 case IEC 60529; IP20 rear IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Maximum operating altitude | 6561.68 ft (2000 m) |
| Protective treatment | Conformal coating conforming to IEC 60068-2-52:Kb/1; Conformal coating conforming to IEC 60068-2-60:Ke |
| Relative humidity | 0…93 % at 104 °F (40 °C), without condensation, 56 days |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 11.200 in (28.448 cm) |
| Package 1 Width | 10.600 in (26.924 cm) |
| Package 1 Length | 14.500 in (36.830 cm) |
| Package weight(Lbs) | 19.820 lb(US) (8.990 kg) |
| GTIN | 3606486926550 |
| Country of origin | LV |
Warranty
| Warranty (in months) | 24 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

REL72505
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.