TM221C40U
Schneider Electric Logic controller, Modicon M221, 40io tr.npn.
Show Specifications
Main Characteristics
| Range of Product | Modicon M221 |
|---|---|
| Product or Component Type | Logic controller |
| [Us] rated supply voltage | 24 V DC |
| Discrete input number | 24, discrete input 4 fast input IEC 61131-2 Type 1 |
| Analogue input number | 2 0...10 V |
| Discrete output type | Transistor |
| Discrete output number | 16 transistor 4 fast output |
| Discrete output voltage | 24 V DC |
| Discrete output current | 0.5 A |
Technical Data
| Discrete I/O number | 40 |
|---|---|
| Maximum number of I/O expansion module | 7 (local I/O-Architecture); 14 (remote I/O-Architecture) |
| Supply voltage limits | 20.4…28.8 V |
| Inrush current | 35 A |
| Maximum power consumption in W | 4.1 W 24 V without I/O expansion module); 16 W 24 V with max number of I/O expansion module) |
| Power supply output current | 0.52 A 5 V expansion bus; 0.3 A 24 V expansion bus |
| Discrete input logic | Sink or source (positive/negative) |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| Analogue input resolution | 10 bits |
| LSB value | 10 mV |
| Conversion time | 1 ms per channel + 1 controller cycle time analog input |
| Permitted overload on inputs | +/- 30 V DC 5 min maximum)analog input; +/- 13 V DC permanent)analog input |
| Voltage state 1 guaranteed | >= 15 V input |
| Voltage state 0 guaranteed | <= 5 V input |
| Discrete input current | 7 mA discrete input; 5 mA fast input |
| Input impedance | 3.4 kOhm discrete input; 100 kOhm analog input; 4.9 kOhm fast input |
| Response time | 35 µs turn-off, I2...I5 input; 5 µs turn-on, I0, I1, I6, I7 fast input; 35 µs turn-on, other terminals input; 5 µs turn-off, I0, I1, I6, I7 fast input; 100 µs turn-off, other terminals input; 300 µs turn-on, turn-off, other terminals output; 5 µs turn-on, turn-off, Q0...Q3 output |
| Configurable filtering time | 0 ms input; 3 ms input; 12 ms input |
| Discrete output logic | Negative logic (sink) |
| Maximum current per output common | 4 A |
| Output frequency | 0.1 kHz output Q4...Q15; 100 kHz fast output (PWM/PLS mode) Q0...Q3 |
| Absolute accuracy error | +/- 1 % of full scale analog input |
| Maximum leakage current | 0.1 mA transistor output |
| Maximum voltage drop | <1 V |
| Mechanical durability | 20000000 cycles transistor output |
| Maximum tungsten load | <12 W output and fast output |
| Protection type | Without protection |
| Memory capacity | 256 kB user application and data RAM 10000 instructions; 256 kB internal variables RAM |
| Data backed up | 256 kB built-in flash memory backup of application and data |
| Data storage equipment | 2 GB SD card optional) |
| Battery type | BR2032 or CR2032X lithium non-rechargeable |
| Backup time | 1 year 77 °F (25 °C) by interruption of power supply) |
| Execution time for 1 KInstruction | 0.3 ms event and periodic task |
| Execution time per instruction | 0.2 µs Boolean |
| Exct time for event task | 60 µs response time |
| Maximum size of object areas | 8000 %MW memory words; 512 %KW constant words; 512 %M memory bits; 255 %C counters; 255 %TM timers |
| Realtime clock | With |
| Clock drift | <= 30 s/month 77 °F (25 °C) |
| Regulation loop | Adjustable PID regulator up to 14 simultaneous loops |
| Positioning functions | PTO 4 pulse/direction 100 kHz); PTO 2 CW/CCW 100 kHz) |
| Function Available | PLS; PWM; Frequency generator |
| Counting input number | 4 fast input (HSC mode) 100 kHz 32 bits |
| Counter function | Pulse/direction; Single phase; A/B |
| Integrated connection type | USB port mini B USB 2.0; Non isolated serial link serial 1 RJ45 RS485; Non isolated serial link serial 2 RJ45 RS232/RS485 |
| Supply | Serial)serial link supply 5 V, <200 mA |
| Transmission rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485; 1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232; 480 Mbit/s USB |
| Communication port protocol | USB port USB - SoMachine-Network; Non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network |
| Local signalling | 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for module error (ERR); 1 LED (green) for SD card access (SD); 1 LED (red) for BAT; 1 LED (green) for SL1; 1 LED (green) for SL2; 1 LED per channel (green) for I/O state |
| Electrical connection | removable screw terminal block for inputs; removable screw terminal block for outputs; terminal block, 3 for connecting the 24 V DC power supply; connector, 4 for analogue inputs; Mini B USB 2.0 connector for a programming terminal |
| Maximum cable distance between devices | Shielded cable <32.8 ft (10 m) fast input; Unshielded cable <98.4 ft (30 m) output; Unshielded cable <98.4 ft (30 m) digital input; Unshielded cable <3.3 ft (1 m) analog input; Shielded cable <9.8 ft (3 m) fast output |
| Insulation | Between input and internal logic 500 V AC; Between fast input and internal logic 500 V AC; Non-insulated between inputs; Between output and internal logic 500 V AC; Non-insulated between analogue input and internal logic; Non-insulated between analogue inputs |
| Marking | CE |
| Mounting support | Top hat type TH35-15 rail IEC 60715; Top hat type TH35-7.5 rail IEC 60715; plate or panel with fixing kit |
| Height | 3.5 in (90 mm) |
| Depth | 2.8 in (70 mm) |
| Width | 6.3 in (160 mm) |
| Net Weight | 1.39 lb(US) (0.63 kg) |
Environment & Certifications
| Standards | IEC 61131-2; UL 508; CAN/CSA C22.2 No. 213; IACS E10; ANSI/ISA 12-12-01 |
|---|---|
| Product Certifications | RCM; cULus; LR; ABS; EAC; DNV-GL; CE; UKCA; cULus HazLoc |
| Environmental characteristic | Ordinary and hazardous location |
| Resistance to electrostatic discharge | 8 kV in air IEC 61000-4-2; 4 kV on contact IEC 61000-4-2 |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3; 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3; 0.9 V/m (1 V/m) 2...2.7 GHz IEC 61000-4-3 |
| Resistance to magnetic fields | 98.4 A/m (30 A/m) 50/60 Hz IEC 61000-4-8 |
| Resistance to fast transients | 2 kV IEC 61000-4-4 power lines); 2 kV IEC 61000-4-4 relay output); 1 kV IEC 61000-4-4 I/O); 1 kV IEC 61000-4-4 Ethernet line); 1 kV IEC 61000-4-4 serial link) |
| Surge withstand | 2 kV power lines (AC) common mode IEC 61000-4-5; 2 kV relay output common mode IEC 61000-4-5; 1 kV I/O common mode IEC 61000-4-5; 1 kV shielded cable common mode IEC 61000-4-5; 0.5 kV power lines (DC) differential mode IEC 61000-4-5; 1 kV power lines (AC) differential mode IEC 61000-4-5; 1 kV relay output differential mode IEC 61000-4-5; 0.5 kV power lines (DC) common mode IEC 61000-4-5 |
| Resistance to conducted disturbances | 10 V 0.15...80 MHz IEC 61000-4-6; 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL); 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL) |
| Electromagnetic emission | Conducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines (AC))0.15…0.5 MHz IEC 55011; Conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines (AC))0.5…300 MHz IEC 55011; Conducted emissions 120...69 dBµV/m QP power lines)10…150 kHz IEC 55011; Conducted emissions 63 dBμV/m QP power lines)1.5…30 MHz IEC 55011; Radiated emissions 40 dBμV/m QP class A 10 m)30…230 MHz IEC 55011; Conducted emissions 79...63 dBμV/m QP power lines)150…1500 kHz IEC 55011; Radiated emissions 47 dBμV/m QP class A 10 m)200…1000 MHz IEC 55011 |
| Immunity to microbreaks | 10 ms |
| Ambient air temperature for operation | 14…131 °F (-10…55 °C) horizontal installation); 14…95 °F (-10…35 °C) vertical installation) |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Relative humidity | 10…95 %, without condensation in operation); 10…95 %, without condensation in storage) |
| IP degree of protection | IP20 with protective cover in place |
| Pollution degree | <= 2 |
| Operating altitude | 0...6561.68 ft (0...2000 m) |
| Storage altitude | 0…9842.5 ft (0…3000 m) |
| Vibration resistance | 3.5 mm 5…8.4 Hz symmetrical rail; 3.5 mm 5…8.4 Hz panel mounting; 1 gn 8.4…150 Hz symmetrical rail; 1 gn 8.4…150 Hz panel mounting |
| Shock resistance | 147 m/s² 11 ms |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 5.6 in (14.3 cm) |
| Package 1 Width | 8.3 in (21.0 cm) |
| Package 1 Length | 4.4 in (11.2 cm) |
| Package weight(Lbs) | 29.3 oz (832.0 g) |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 11.8 in (30.0 cm) |
| Package 2 Width | 15.7 in (40.0 cm) |
| Package 2 Length | 23.6 in (60.0 cm) |
| Package 2 Weight | 23.422 lb(US) (10.624 kg) |
| GTIN | 3606485408637 |
| Country of origin | TW |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

TM221C40U
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.