TM3SAK6R
Schneider Electric Modicon TM3 Safety safety module, Modicon TM3, 3 function, Cat 4 PL e, SIL CL3, screw, 24V DC.
Show Specifications
Main Characteristics
| Range of Product | Modicon TM3 Safety |
|---|---|
| Product or Component Type | Safety module |
| Safety module application | For emergency stop, switch, sensing mat/edges or safety light curtain monitoring |
| Function of module | Emergency stop monitoring 1-channel wiring; Emergency stop monitoring 2-channel wiring; Monitoring of a movable guard with 2 switches and automatic start; Monitoring of a movable guard; Multiple emergency stop monitoring 2-channel wiring; Proximity sensor monitoring PNP/PNP; Proximity sensor monitoring PNP/NPN; Sensing mat and edges monitoring; Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP; Monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN |
| Safety level | Can reach PL e/category 4 ISO 13849-1 2008; Can reach PL e/category 4 ISO 13849-2 2012; Can reach SILCL 3 IEC 62061 2005; Can reach SIL 3 IEC 61508 2010 |
Technical Data
| Safety reliability data | DC = 95 % ISO 13849-1; PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A; PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A; MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A; MTTFd = 85 years ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A; SFF = 95 % IEC 61508-1; HFT = 1 IEC 61508-1; Type = A IEC 61508-1 |
|---|---|
| Synchronisation time between inputs | Unlimited; 2 or 4 s depending of wiring configurable by software |
| Connections - terminals | Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34; Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals; Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals; Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals; Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals |
| Output type | Relay instantaneous opening, 3 NO, potential free |
| Number of safety circuits | 3 NO relay instantaneous opening |
| Maximum switching voltage | 230 V AC-15 50 Hz relay instantaneous opening); 24 V DC-13 relay instantaneous opening) |
| [Us] rated supply voltage | 24 V - 15...20 % DC |
| Power consumption in W | 0.2 W 5 V DC; 3.6 W 24 V DC |
| Input protection type | Internal, electronic |
| [Uc] control circuit voltage | 24 V DC |
| Maximum cable distance between devices | 98.4 ft (30 m) |
| Breaking capacity | 4 A 24 V 50 ms DC-13 relay output |
| Output thermal current | 6 A per relay relay output |
| [Ith] conventional free air thermal current | 18 A |
| Associated fuse rating | 4 A gG or gL relay output IEC 60947-5-1; 6 A fast blow relay output IEC 60947-5-1 |
| Minimum output current | 10 mA relay output |
| Output voltage | 10 V relay output |
| Maximum response time on input open | 40 ms |
| [Ui] rated insulation voltage | 300 V 2)IEC 60647-5-1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60647-5-1 |
| Current consumption | 100 mA 24 V DC external supply |
| Local signalling | 8 LEDs (green/red) for user |
| Electrical Connection | Screw terminal |
| Product compatibility | Safety light curtains EN/IEC 61496-1 (type 4); Sensing mat/edges EN 1760-1 |
| Standards | ISO 13849-1:2008; ISO 13849-2:2012; IEC 62061:2005; IEC 61508:2010; IEC 60947-5-1:2010; IEC 61131-2:2007; IEC 60204-1:2005; IEC 60204-1:2009/A1; IEC 61010-1:2010; EN 50581:2012 |
| Product Certifications | TÜV; UL 61010-2-201; EAC; CSA Haz Loc Class 1 Division 2 (pending); CSA 61010-2-201 (pending); RCM; ANSI Haz Loc Class 1 Division 2 (pending) |
| Marking | UL; CE; RCM; EAC; EFUP 10; TÜV; CSA |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2; Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2; Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3; Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3; Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8; Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4; Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4; 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5; Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6; Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011; Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011 |
| Mounting support | Top hat type TH35-7.5 rail IEC 60715; Top hat type TH35-15 rail IEC 60715; wall mount using attached fasteners |
| Height | 3.7 in (94 mm) |
| Depth | 2.9 in (73 mm) |
| Width | 1.7 in (43.7 mm) |
| Net Weight | 0.42 lb(US) (0.19 kg) |
Environment & Certifications
| Standards | IEC 60947-1; IEC 60204-1; EN 1088/ISO 14119; IEC 60947-5-1; ISO 13850 |
|---|---|
| Resistance to electrostatic discharge | 8 kV in air IEC 61000-4-2; 6 kV on contact IEC 61000-4-2 |
| Resistance to electromagnetic fields | 9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3; 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3; 0.9 V/m (1 V/m) 2 GHz...3 GHz IEC 61000-4-3 |
| Resistance to magnetic fields | 98.4 A/m (30 A/m) 50/60 Hz IEC 61000-4-8 |
| Resistance to fast transients | 3 kV power lines (DC) DC)IEC 61000-4-4; 2 kV I/O linesIEC 61000-4-4 |
| Surge withstand | 1 kV power lines (DC) differential mode IEC 61000-4-5 DC; 1 kV power lines (DC) common mode IEC 61000-4-5 DC |
| Resistance to conducted disturbances | 10 V 0.15...80 MHz IEC 61000-4-6 |
| Electromagnetic emission | Radiated emissions 50 dBµV/m class A 24 V DC)30…230 Hz IEC 61131-3; Radiated emissions 57 dBµV/m class A 24 V DC)230…1000 Hz IEC 61131-3 |
| Ambient Air Temperature for Operation | 14…131 °F (-10…55 °C) horizontal installation |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Relative humidity | 10…95 %, without condensation in operation); 10…95 %, without condensation in storage) |
| IP degree of protection | IP20 terminals)IEC 60529 |
| Pollution degree | 2 |
| Operating altitude | 0...6561.68 ft (0...2000 m) |
| Storage altitude | 0…9842.5 ft (0…3000 m) |
| Vibration resistance | +/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
| Mechanical robustness | Bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27 |
Packaging & Logistics
| Nbr. of units in pkg. | 1 |
|---|---|
| Package 1 Height | 2.953 in (7.500 cm) |
| Package 1 Width | 4.173 in (10.600 cm) |
| Package 1 Length | 4.921 in (12.500 cm) |
| Package weight(Lbs) | 10.123 oz (287.000 g) |
| Number of Units in Package 2 | 18 |
| Package 2 Height | 11.811 in (30.000 cm) |
| Package 2 Width | 11.811 in (30.000 cm) |
| Package 2 Length | 15.748 in (40.000 cm) |
| Package 2 Weight | 12.154 lb(US) (5.513 kg) |
| GTIN | 3606485393032 |
| Country of origin | FR |
Warranty
| Warranty (in months) | 18 |
|---|
Pairs well with
Worldwide delivery, dispatched from Erbil
Technical support before and after you order
Genuine parts from authorised manufacturers
Obsolete and hard-to-find items sourced

TM3SAK6R
If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, within 24 hours on weekdays.
-
Shipping
We ship worldwide from our warehouse in Erbil, Iraq, and deliver across Baghdad and all governorates. Stocked lines dispatch quickly; items sourced to order have their lead time confirmed in writing with your quote.
-
Technical support
Not sure which part you need, or whether an alternative is compatible? Send us the part number, the equipment it goes into, or a photo of the nameplate and our team will confirm the correct item before you order.
WhatsApp +964 781 287 9696 or sales@alnajahpower.com.
-
Pricing and quotes
Prices are not shown online because they depend on quantity, specification and current availability. Add the items you need to your quote list and send it — we reply within one business day with pricing and lead time.
-
Contact us
Alnajah Power
Makhmur Str. 83, Erbil 44020, IraqPhone / WhatsApp: +964 781 287 9696
sales@alnajahpower.comSaturday to Thursday, 09:00 – 18:00.
FAQs
Please read our FAQs page to find out more.
Do you supply genuine products?
We supply genuine industrial automation and electrical products from leading manufacturers including Siemens, ABB, Schneider Electric, Phoenix Contact, and Eaton. Product authenticity and quality are our priority.
Can I request a quotation?
Yes. If pricing is not displayed or you require multiple items, simply use the “Request a Quote” button or contact our sales team for a customized quotation.
Do you ship internationally?
Yes. We provide worldwide shipping and can deliver products to customers across Europe, the Middle East, Asia, and other international destinations.
Can you source obsolete or hard-to-find parts?
Yes. We specialize in sourcing discontinued, obsolete, and difficult-to-find industrial automation components through our global supplier network.
What industries do you serve?
We support customers in manufacturing, oil & gas, energy, utilities, water treatment, infrastructure, and industrial automation sectors.